PVI Industries Water Heater 75 L 225A-PVX
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
1 Yearly Water Heater Check
WARNING: Use exact, Factory authorized, replacement parts and label all wires prior to disconnection. Verify proper operation after servicing. Incorrect parts substitution and wiring errors can cause damage, improper operation, fire, carbon monoxide, exposure to toxic fumes or other unexpected and unsafe conditions that can result in fire, personal injury or death.
Inspection of Appliance and Venting System
Check all joints and pipe connections for tightness, corrosion or deterioration
Check the electronic-ignition system for quick ignition and a proper flame signal
Check all safety controls including thermostats for proper operation
Check safety shut-off valves for operation and tightness
Professional Inspection
Have the entire system, including the burner, heat exchanger, and venting system, inspected by a qualified service agency
12 Monthly Water Heater Maintenance
Initial Inspection
Schedule annual service call by qualified service agency
Check for piping leaks around pumps, relief valves, and tank connections
Is the area free from combustible materials, gasoline, and other flammable vapors or liquids?
Venting and Drainage Inspection
Visually inspect venting system for proper function, deterioration or leakage
Inspect condensate drain and ensure condensate is directed to an appropriate condensate system or drain
Valve and Safety Devices Check
Check temperature and pressure relief valve according to manufacturer’s instructions
1 Daily Water Heater Check
Obstruction and Safety Check
Remove any obstruction to the flow of combustion or ventilation air to the unit
Ensure area is free from combustible materials
Gauges and Indicators Check
Check gauges, monitors, and indicators
1 Monthly Water Heater Maintenance
Condensate Drain System Maintenance
Check condensate drain system
Refill the condensate neutralizer with limestone
Note any changes in the refill interval for the condensate neutralizer
Visually inspect venting system for proper function, deterioration or leakage
Low-Water Cutoff and Alarm Check
Is the low-water cutoff operating correctly?
Is the alarm functioning properly?
Water Heater Maintenance
WARNING
Document any wiring changes and verify proper operation after servicing
Inspection and Cleaning
Is the appliance installed in a dust or dirt contaminated atmosphere?
Inspect for soot on the heat exchanger or in the flue
Inspect and clean the heat exchanger if necessary
Inspect and clean the burner and/or heat exchanger
Inspect the integral circulation pump for gasket leaks or failure
Safety and Maintenance Checks
Access the parts list for your equipment in MaintainX.
Tab,Burner Grounding
128315
Gasket,Flange Burner 1/8 232 Craneglas 5.750 Id
126509
Gasket, Ignitor 1/8 232 Craneglas Y271
111791
Igniter, Hot Surface Norton #271Y Mb478843
107774
Nut, Wing 1/4 X 20 Nc Steel Zinc Plt
3475
Tab,Burner Grounding
128315
Gasket,Flange Burner 1/8 232 Craneglas 5.750 Id
126509
Gasket, Ignitor 1/8 232 Craneglas Y271
111791
Igniter, Hot Surface Norton #271Y Mb478843
107774
Nut, Wing 1/4 X 20 Nc Steel Zinc Plt
3475
Tab,Burner Grounding
128315
Gasket,Flange Burner 1/8 232 Craneglas 5.750 Id
126509
Gasket, Ignitor 1/8 232 Craneglas Y271
111791
Igniter, Hot Surface Norton #271Y Mb478843
107774
Nut, Wing 1/4 X 20 Nc Steel Zinc Plt
3475
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX