MaintainX Asset Hub logo
EnterprisePricing
PVI Industries

PVI Industries Water Heater 100 L 225A-PVX

Need answers fast?
Explore the manual using AI.

PVI Industries Water Heater 100 L 225A-PVX
PVI Industries Water Heater 100 L 225A-PVX

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for PVI Industries Water Heater 100 L 225A-PVX

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

PVI Industries Water Heater 100 L 225A-PVX

PVI Industries Water Heater 100 L 225A-PVX

Create an account to install this asset package.

Maintenance Plans for PVI Industries Water Heater Model 100 L 225A-PVX

Integrate maintenance plans directly into your work orders in MaintainX.

12 Monthly Water Heater Maintenance

Check mark

Schedule annual service call by qualified service agency

Check mark

Check for piping leaks around pumps, relief valves, and tank connections

Check mark

Repair piping leaks if found

Check mark

Ensure area is free from combustible materials, gasoline, and other flammable vapors or liquids

Check mark

Visually inspect venting system for proper function, deterioration or leakage

Check mark

Check temperature and pressure relief valve

Check mark

Inspect condensate drain and ensure proper direction to an appropriate system or drain

Check mark

Check all operation of safety devices

Check mark

Inspect burner and gas train components for wear or deterioration

Run this procedureArrow right

1 Monthly Water Heater Maintenance

Check mark

Condensate Drain System Maintenance

Check mark

Check condensate drain system

Check mark

Refill the condensate neutralizer with limestone

Check mark

Note any changes needed for the condensate neutralizer change interval

Check mark

Venting System Inspection

Check mark

Visually inspect venting system for proper function

Check mark

Check for deterioration or leakage in the venting system

Check mark

Low-Water Cutoff and Alarm Check

Check mark

Confirm the low-water cutoff is operating

Run this procedureArrow right

Water Heater Maintenance

Check mark

WARNING

Check mark

Describe any issues found during inspection

Check mark

Inspect and clean the heat exchanger

Check mark

Burner and Heat Exchanger Inspection and Cleaning

Check mark

Turn off main power to unit

Check mark

Turn off gas supply

Check mark

Document the disassembly process

Check mark

Disconnect electrical components

Check mark

Remove the metal cover on top of the appliance

Run this procedureArrow right

6 Monthly Water Heater Testing

Check mark

Low-water-cut-off Testing

Check mark

Test Low-water-cut-off (if equipped)

Check mark

Reset Low-water-cut-off

Check mark

Electronic-ignition Flame Failure Detection System Testing

Check mark

Test the electronic-ignition flame failure detection system

Check mark

Reset the electronic-ignition flame failure detection system

Run this procedureArrow right

1 Yearly Water Heater Check

Check mark

WARNING: Use exact, Factory authorized, replacement parts and label all wires prior to disconnection. Verify proper operation after servicing. Incorrect parts substitution and wiring errors can cause damage, improper operation, fire, carbon monoxide, exposure to toxic fumes or other unexpected and unsafe conditions that can result in fire, personal injury or death.

Check mark

Inspection of Appliance and Venting System

Check mark

Check all joints and pipe connections for tightness, corrosion or deterioration

Check mark

Check the electronic-ignition system for quick ignition and a proper flame signal

Check mark

Check all safety controls including thermostats for proper operation

Check mark

Check safety shut-off valves for operation and tightness

Check mark

Professional Inspection

Check mark

Have the entire system, including the burner, heat exchanger, and venting system, inspected by a qualified service agency

Run this procedureArrow right

Parts for PVI Industries Water Heater 100 L 225A-PVX

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

Tab,Burner Grounding

128315

Gasket,Flange Burner 1/8 232 Craneglas 5.750 Id

126509

Gasket, Ignitor 1/8 232 Craneglas Y271

111791

Igniter, Hot Surface Norton #271Y Mb478843

107774

Nut, Wing 1/4 X 20 Nc Steel Zinc Plt

3475

Tab,Burner Grounding

128315

Gasket,Flange Burner 1/8 232 Craneglas 5.750 Id

126509

Gasket, Ignitor 1/8 232 Craneglas Y271

111791

Igniter, Hot Surface Norton #271Y Mb478843

107774

Nut, Wing 1/4 X 20 Nc Steel Zinc Plt

3475

Tab,Burner Grounding

128315

Gasket,Flange Burner 1/8 232 Craneglas 5.750 Id

126509

Gasket, Ignitor 1/8 232 Craneglas Y271

111791

Igniter, Hot Surface Norton #271Y Mb478843

107774

Nut, Wing 1/4 X 20 Nc Steel Zinc Plt

3475

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from PVI Industries

Explore Other Assets