

Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Sullair Rotary Vacuum System VS16 30HP: Encl
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
Filter Element Replacement
6.7 PARTS REPLACEMENT AND ADJUSTMENT PROCEDURES
FILTER ELEMENT REPLACEMENT
Refer to Figure 6-1.
Using a strap wrench, remove the old element and gasket.
Clean the gasket seating surface.
Apply a light film of fluid to the new gasket.
Hand tighten the new element until the new gasket is seated in the gasket groove.
Continue tightening element by hand an additional 1/2 to 3/4 turn.
Restart the machine and check for leaks.
Fluid Return / Sight Glass Maintenance
Always perform maintenance on both fluid return/sight glasses at the same time.
Disconnect the tubes at the tops of the sight glass assemblies.
Unscrew male connector (for left-side glass), or the straight thread tube connector (for right-side glass) from sight glass/orifice blocks.
Remove used filter assembly, and replace with new assembly.
Coat/lubricate the O-rings will silicone grease.
Reattach the connectors to the sight glass/orifice.
Sign off on the fluid return/sight glass maintenance
Initial 50 Hours Vacuum System Maintenance
Maintenance after initial 50 hours of operation
Clean the return line strainer(s)
Clean the return line orifice(s) if so equipped
Clean the vacuum unit gear housing, bearing and shaft seal orifices
Warning: Care must be taken not to damage the shaft
Clean the fluid pump suction strainer
Sign off on the vacuum system maintenance
Control System Adjustment
Refer to Figure 6-4. Prior to adjusting the Control System, it is necessary to determine the desired operating vacuum range.
The following explanation applies to a typical installation with a desired operating vacuum of 20 in-Hg. (508mm). This information will apply to a vacuum unit with any other operating vacuum except for the stated vacuum.
The vacuum regulator should be adjusted for the vacuum at which modulation of gas delivery should begin. In this case, the vacuum will be 20 in-Hg. (508mm).
The regulator is adjusted by loosening the jam nut on the end of the cone shaped spring cover of the vacuum regulator.
When the jam nut is loose, turn the adjusting screw clockwise to increase or counterclockwise to decrease the setting.
Above 20 in-Hg. (508mm), the regulator will allow atmospheric pressure to flow into the control chamber of the Sullicon Control.
At this time, the Sullicon Control lever should start to move.
If the vacuum unit is equipped with the optional dual control, the vacuum switch contacts should open at 23 in-Hg. (584mm) and reclose at 20 in-Hg. (508mm).
Sign off on the control system adjustment
4000 Hourly / 6 Monthly Fluid Filter Maintenance
Fluid Filter Maintenance
Filter maintenance gauge indicates replacement
Enter the machine's hour meter reading
Enter the date of the last fluid filter replacement
Fluid change performed
Upload a photo of the new fluid filter
Sign off on the fluid filter maintenance
Access the parts list for your equipment in MaintainX.
Vacuum Gauge
250042-041
Inlet Filter
250024-659
Vacuum Switch
02250164-176
Inlet Check Valve
250028-224
Butterfly Valve
040640
Vacuum Gauge
250042-041
Inlet Filter
250024-659
Vacuum Switch
02250164-176
Inlet Check Valve
250028-224
Butterfly Valve
040640
Vacuum Gauge
250042-041
Inlet Filter
250024-659
Vacuum Switch
02250164-176
Inlet Check Valve
250028-224
Butterfly Valve
040640
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX













