MaintainX Asset Hub logo
EnterprisePricing
Quincy

Quincy Compressor 340

Need answers fast?
Explore the manual using AI.

Quincy Compressor 340
Quincy Compressor 340

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Quincy Compressor 340

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Quincy Compressor 340

Quincy Compressor 340

Create an account to install this asset package.

Maintenance Plans for Quincy Compressor Model 340

Integrate maintenance plans directly into your work orders in MaintainX.

Pressure Switch Adjustment

Check mark

Preparation

Check mark

Ensure the compressor is disconnected from the power supply

Check mark

Verify that all safety precautions from SECTION 5, Stopping For Maintenance, are followed

Check mark

Pressure Switch Adjustment

Check mark

Remove the pressure switch cover

Check mark

Record the current air pressure reading

Check mark

Is the compressor running?

Check mark

Adjust the spring loaded adjustment screw

Check mark

Record the new air pressure reading

Run this procedureArrow right

1 Daily Compressor Check

Check mark

Pre-Start Checks

Check mark

Check oil level in crankcase

Check mark

Drain liquid from the air receiver and moisture trap

Check mark

Turn on cooling water for water-cooled units

Check mark

Starting the Compressor

Check mark

Jog the starter button and check compressor rotation

Check mark

Adjust pilot valve for continuous run units if applicable

Check mark

Start compressor per factory instructions

Check mark

Operational Checks

Run this procedureArrow right

40 Hourly / 1 Weekly Compressor Maintenance

Check mark

Pressure Relief Valves

Check mark

Manually operate the pressure relief valves to ensure they are working

Check mark

Cooling Surfaces Maintenance

Check mark

Clean the cooling surfaces of the intercooler

Check mark

Clean the cooling surfaces of the compressor

Check mark

Leak Inspection

Check mark

Check the compressor for air leaks

Check mark

Check the compressed air distribution system for leaks

Check mark

Oil Inspection

Run this procedureArrow right

Initial 100 Hours / 1 Months Oil Change

Check mark

Pre-Operation Checks

Check mark

Ensure all necessary parts are in place

Check mark

Check the lubricant level in the crankcase

Check mark

Oil Change Procedure

Check mark

Has the compressor been operated for 100 hours or 1 month?

Check mark

Replace the break-in lubricant with QuinCip lubricant

Check mark

Post-Operation Checks

Check mark

Is the lubricant level within the recommended range after replacement?

Check mark

Verify ambient temperature conditions

Run this procedureArrow right

1000 Hourly / 6 Monthly Compressor Maintenance

Check mark

Oil Change

Check mark

Is Quin-Cip oil being used?

Check mark

Change oil if 1000 hours or 6 months have passed, whichever occurs first

Check mark

Was the oil changed more frequently due to harsher conditions?

Check mark

Compressor Valve Inspection

Check mark

Inspect compressor valves for leakage

Check mark

Inspect compressor valves for carbon build-up

Check mark

Crankcase and Oil Sump Maintenance

Check mark

Clean oil sump strainer screen inside the crankcase with safety solvent

Run this procedureArrow right

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Quincy

Explore Other Assets