Quincy Low Pressure Rotary Screw Compressor QSLP 60
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
Shaft Fluid Seal Scavenge System Inspection
Scavenge Line Inspection
Check that the scavenge line fitting at the bottom of the scavenge line cavity is open and clear
Ensure the scavenge line is not plugged
Check Valve Performance Inspection
Inspect the scavenge line check valve for sticking
Is the check valve stuck in the open position?
Is the check valve stuck in the closed position?
Post Inspection Actions
Describe any issues found during inspection
Initial 500 Hourly Fluid Filter Replacement
Preparation
Ensure the equipment is turned off and cooled down
Gather necessary tools and replacement filter
Filter Replacement
Remove the complete cartridge
Install the new genuine Quincy replacement filter
Post Replacement Check
Check for any leaks after replacement
Ensure all tools are removed from the work area
8 Hourly Compressor Check
Gauge and Indicator Monitoring
Record the pressure gauge reading
Record the temperature gauge reading
Are all gauges and indicators showing normal operation?
Fluid Level and Leak Inspection
Check and record the fluid level
Is the fluid level within the normal range?
Inspect for any fluid leaks
Noise and Vibration Check
4000 Hourly / 1 Yearly Air/Fluid Separator Element Replacement
Pre-Replacement Checks
Is the Differential Pressure Indicator showing a need for replacement?
Is there excessive fluid carryover with normal scavenging system, fluid temperature, and running fluid level?
Has it been 4,000 hours since the last replacement?
Has it been one year since the last replacement?
Replacement Procedure
Ensure the compressor is turned off and depressurized before starting the replacement.
Carefully remove the air/fluid separator element without removing the staples.
Inspect the separator element for any dents or punctures.
1000 Hourly Fluid Filter Replacement
Pre-Replacement Checks
Is the fluid up to its operating temperature?
Has the fluid filter maintenance indicator been checked?
Replacement Conditions
Replace the filter cartridge if any of the following conditions are met
Filter Replacement
Remove the complete filter cartridge
Install a new genuine Quincy replacement filter
Post-Replacement Monitoring
Access the parts list for your equipment in MaintainX.
Seal Installation Fluid
140902
Seal Installation Fluid
140902
Seal Installation Fluid
140902
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX