MaintainX Asset Hub logo
EnterprisePricing
Quincy

Quincy Low Pressure Rotary Screw Compressor QSLP 125

Need answers fast?
Explore the manual using AI.

Quincy Low Pressure Rotary Screw Compressor QSLP 125
Quincy Low Pressure Rotary Screw Compressor QSLP 125

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Quincy Low Pressure Rotary Screw Compressor QSLP 125

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Quincy Low Pressure Rotary Screw Compressor QSLP 125

Quincy Low Pressure Rotary Screw Compressor QSLP 125

Create an account to install this asset package.

Maintenance Plans for Quincy Low Pressure Rotary Screw Compressor Model QSLP 125

Integrate maintenance plans directly into your work orders in MaintainX.

Water-cooled Heat Exchangers Maintenance

Check mark

Gasket Replacement

Check mark

Replace gaskets when removing end castings

Check mark

Soak gaskets in oil to prevent corrosion and ensure a tight seal

Check mark

Zinc Anode Inspection

Check mark

Inspect zinc anodes two weeks after initial startup

Check mark

Determine future inspection intervals based on corrosion rate

Check mark

Replace zinc anodes when 70% of zinc volume is consumed

Check mark

Water Chamber Draining

Check mark

Drain water chambers to protect from freezing temperatures

Run this procedureArrow right

Initial 500 Hourly Fluid Filter Replacement

Check mark

Preparation

Check mark

Ensure the equipment is turned off and cooled down

Check mark

Gather necessary tools and replacement filter

Check mark

Filter Replacement

Check mark

Remove the complete cartridge

Check mark

Install the new genuine Quincy replacement filter

Check mark

Post Replacement Check

Check mark

Check for any leaks after replacement

Check mark

Dispose of the old filter according to local regulations

Run this procedureArrow right

Differential Pilot Valve Adjustment

Check mark

Initial Setup

Check mark

Open the manual vent valve to allow the compressor to exhaust air to the outside

Check mark

Start the unit

Check mark

Pressure Adjustment

Check mark

Monitor the air pressure as the valve is slowly closed

Check mark

Is the air pressure at the desired modulation point (38 PSIG)?

Check mark

Adjust the screw on the bottom of the differential pilot valve

Check mark

Adjust pressure by turning the screw

Check mark

Verification

Run this procedureArrow right

4000 Hourly / 1 Yearly Air/Fluid Separator Element Replacement

Check mark

Pre-Replacement Checks

Check mark

Is the Differential Pressure Indicator showing a need for replacement?

Check mark

Is there excessive fluid carryover with normal scavenging system, fluid temperature, and running fluid level?

Check mark

Has it been 4,000 hours since the last replacement?

Check mark

Has it been one year since the last replacement?

Check mark

Replacement Procedure

Check mark

Ensure the compressor is turned off and depressurized before starting the replacement.

Check mark

Carefully remove the air/fluid separator element without removing the staples.

Check mark

Inspect the separator element for any dents or punctures before installation.

Run this procedureArrow right

Shaft Fluid Seal Replacement

Check mark

Preparation and Safety Precautions

Check mark

Ensure you have the complete illustrated instructions from Quincy distributor

Check mark

Verify availability of special tools for seal replacement

Check mark

Ensure a clean working environment

Check mark

Handle all components with care to avoid damage

Check mark

Shaft Seal Removal - Triple Lip Type Seal

Check mark

Remove the drive coupling guards and coupling halves

Check mark

Remove the drive coupling hub and key from the compressor shaft

Check mark

Remove the four bolts and lock washers securing the seal adapter to the suction housing

Run this procedureArrow right

Parts for Quincy Low Pressure Rotary Screw Compressor QSLP 125

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

Seal Installation Fluid

140902

Seal Installation Fluid

140902

Seal Installation Fluid

140902

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Quincy

Explore Other Assets