MaintainX Asset Hub logo
EnterprisePricing
Lochinvar

Lochinvar Condensing Boiler OFN3501

Need answers fast?
Explore the manual using AI.

Lochinvar Condensing Boiler OFN3501
Lochinvar Condensing Boiler OFN3501

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Lochinvar Condensing Boiler OFN3501

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Lochinvar Condensing Boiler OFN3501

Lochinvar Condensing Boiler OFN3501

Create an account to install this asset package.

Maintenance Plans for Lochinvar Condensing Boiler Model OFN3501

Integrate maintenance plans directly into your work orders in MaintainX.

Thermostat Circuit Check

Check mark

Preparation

Check mark

Disconnect the two external wires connected to the enable terminals on the connection board.

Check mark

Voltage Check

Check mark

Connect a voltmeter across the two incoming wires and close each thermostat, zone valve, and relay in the external circuit one at a time. Record the voltmeter reading across the incoming wires.

Check mark

Is there any voltage reading?

Check mark

Troubleshooting

Check mark

If a voltage occurs, was the external wiring checked and corrected?

Check mark

Final Steps

Check mark

Reconnect the external thermostat circuit wires to the connection board.

Run this procedureArrow right

Water Piping Check

Check mark

Leak Inspection

Check mark

Check system piping for leaks

Check mark

Air Venting

Check mark

Vent any remaining air from the system using manual vents

Run this procedureArrow right

Water System Check

Check mark

Fill and Test Water System

Check mark

Ensure water meets manual requirements before filling system

Check mark

Close the following components

Check mark

Fill to correct system pressure

Check mark

Enter the minimum cold water fill pressure

Check mark

Did the pressure rise when the boiler was turned ON?

Check mark

Check the system thoroughly for any leaks during initial fill and boiler startup

Check mark

Describe any leaks found and repairs made

Check mark

Purge Air from Water System

Run this procedureArrow right

Inlet Gas Supply Check

Check mark

Warning!

Check mark

Pre-Check Preparations

Check mark

Turn the main power switch to the “OFF” position.

Check mark

Shut off gas supply at the manual gas valve in the gas piping to the appliance.

Check mark

Manometer Setup

Check mark

Remove the 1/8" pipe plug on the flange to the factory supplied gas shutoff valve and install a suitable 1/8" fitting for the manometer tubing.

Check mark

Place the tubing of the manometer over the tap once the 1/8" fitting is installed.

Check mark

Gas Supply and Power On

Check mark

Slowly turn on the gas supply at the factory installed manual gas valve.

Run this procedureArrow right

Initial Boiler Cleaning

Check mark

System Flushing

Check mark

Flush the entire heating system prior to fill and start-up

Check mark

System Cleaning

Check mark

Clean the entire heating system with an approved pre-commissioning cleaner

Check mark

Specify the manufacturer's recommendation followed for cleaning

Check mark

Filter Cleaning

Check mark

Clean all water filtering devices in the system

Check mark

System Refill

Check mark

Flush the cleaning solution out of the entire system

Run this procedureArrow right

Parts for Lochinvar Condensing Boiler OFN3501

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

Outdoor Kit Models 751 - 2001

100301827

Outdoor Kit Models 2501 - 3001

100313289

Outdoor Kit Models 3501

100308477

Outdoor Kit Models 4001 - 5001

100313290

Outdoor Kit Models 6001

100313291

Outdoor Kit Models 751 - 2001

100301827

Outdoor Kit Models 2501 - 3001

100313289

Outdoor Kit Models 3501

100308477

Outdoor Kit Models 4001 - 5001

100313290

Outdoor Kit Models 6001

100313291

Outdoor Kit Models 751 - 2001

100301827

Outdoor Kit Models 2501 - 3001

100313289

Outdoor Kit Models 3501

100308477

Outdoor Kit Models 4001 - 5001

100313290

Outdoor Kit Models 6001

100313291

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Lochinvar

Explore Other Assets