

Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Honeywell Fixed Gas Detector SPLLH1XAXWXNZZ
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
Sensor Replacement
WARNING
Use only genuine replacement sensors specifically for use with Sensepoint XCL.
CAUTION
Do not replace the sensor without first removing power to the Sensepoint XCL or placing the sensor into the sensor maintenance mode.
Smartphone Method
Connect your smartphone to the Sensepoint XCL via Bluetooth.
Tap the Maintenance button and select Change Sensor.
Follow the on-screen instructions.
Manual Method
Sensor Calibration
NOTE
Describe any issues encountered during calibration
Preparation
Ensure the gas detector is powered on
Is the Bluetooth® link version being used with a smartphone app?
Inhibit Mode Activation
Press and hold the UP button for 2 seconds to activate inhibit mode
Is the yellow indicator on?
Zero Calibration
6 Monthly Bump Testing
Preparation
Connect your smartphone with the target gas detector via Bluetooth.
Place the detector in inhibit mode using the mobile app.
Bump Test Execution
Connect a cylinder of reference gas to the target detector using a suitable tube.
Apply the bump test gas to the detector.
Specific Instructions for CO Versions
Apply 100 ppm of carbon monoxide at a flow rate of 300 ml/min for 3 minutes.
Post-Test Actions
Access the parts list for your equipment in MaintainX.
Sensepoint XCL Calibration/Flow Cap
SPXCLCAL
Sensepoint XCL Duct Mount Kit
SPXCLDMK
Sensepoint Fixed Remote Gassing Port
SPXCLRGP
Sensepoint XCL M20 Cable Glands, Black (10 Pieces Each Pack)
SPXCLGLD
Sensepoint XCL M20 Cable Glands, White (10 Pieces Each Pack)
SPXCLGLW
Sensepoint XCL Calibration/Flow Cap
SPXCLCAL
Sensepoint XCL Duct Mount Kit
SPXCLDMK
Sensepoint Fixed Remote Gassing Port
SPXCLRGP
Sensepoint XCL M20 Cable Glands, Black (10 Pieces Each Pack)
SPXCLGLD
Sensepoint XCL M20 Cable Glands, White (10 Pieces Each Pack)
SPXCLGLW
Sensepoint XCL Calibration/Flow Cap
SPXCLCAL
Sensepoint XCL Duct Mount Kit
SPXCLDMK
Sensepoint Fixed Remote Gassing Port
SPXCLRGP
Sensepoint XCL M20 Cable Glands, Black (10 Pieces Each Pack)
SPXCLGLD
Sensepoint XCL M20 Cable Glands, White (10 Pieces Each Pack)
SPXCLGLW
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX













