

Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Honeywell Fixed Gas Detector SPLLC2XAXWXNZZ
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
Sensor Calibration
NOTE
Ensure the gas detector is powered on
Inhibit Mode Activation
Press and hold the UP button for 2 seconds to activate inhibit mode
Is the yellow indicator on?
Voltmeter Connection
Connect the positive probe of a voltmeter to the positive terminal
Connect the negative probe to the negative terminal of the output voltage monitor
Zero Calibration
Sensor Replacement
WARNING: Use only genuine replacement sensors
CAUTION: Power down or enter maintenance mode before replacing sensor
Preparation
Is the Sensepoint XCL powered down or in maintenance mode?
Connect smartphone to Sensepoint XCL via Bluetooth
Tap the Maintenance button and select Change Sensor
Manual Sensor Replacement
Press and hold the UP button for 10 seconds to enter sensor replacement mode
Pull out the gas sensor to remove it
6 Monthly Bump Testing
Preparation
Connect your smartphone with the target gas detector via Bluetooth.
Place the detector in inhibit mode using the mobile app.
Bump Test Execution
Connect a cylinder of reference gas to the target detector using a suitable tube.
Apply the bump test gas to the detector.
Did the detector pass the bump test?
Post-Test Actions
If the detector fails, was it checked and calibrated if necessary?
Access the parts list for your equipment in MaintainX.
Sensepoint XCL Calibration/Flow Cap
SPXCLCAL
Sensepoint XCL Duct Mount Kit
SPXCLDMK
Sensepoint Fixed Remote Gassing Port
SPXCLRGP
Sensepoint XCL M20 Cable Glands, Black (10 Pieces Each Pack)
SPXCLGLD
Sensepoint XCL M20 Cable Glands, White (10 Pieces Each Pack)
SPXCLGLW
Sensepoint XCL Calibration/Flow Cap
SPXCLCAL
Sensepoint XCL Duct Mount Kit
SPXCLDMK
Sensepoint Fixed Remote Gassing Port
SPXCLRGP
Sensepoint XCL M20 Cable Glands, Black (10 Pieces Each Pack)
SPXCLGLD
Sensepoint XCL M20 Cable Glands, White (10 Pieces Each Pack)
SPXCLGLW
Sensepoint XCL Calibration/Flow Cap
SPXCLCAL
Sensepoint XCL Duct Mount Kit
SPXCLDMK
Sensepoint Fixed Remote Gassing Port
SPXCLRGP
Sensepoint XCL M20 Cable Glands, Black (10 Pieces Each Pack)
SPXCLGLD
Sensepoint XCL M20 Cable Glands, White (10 Pieces Each Pack)
SPXCLGLW
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX













