Goodman Gas Furnace GMES961205DNAA
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
Electronic Air Cleaner Inspection
Pre-Inspection Setup
Ensure the air cleaner is installed in the correct position (not with the access door facing down).
Verify the air cleaner is located in the return air duct next to the blower compartment.
Electronic Air Cleaner Inspection
Check accessibility for periodic inspection and cleaning of pre-filters and electronic cells.
Inspect and clean the pre-filters.
Inspect and clean the electronic cells.
Media Air Cleaner Inspection
Check accessibility for periodic inspection and replacement of the Media Air Cleaner filter cartridge.
Pressure Regulator Adjustment
Safety Precautions
Connect a monometer to the outlet tap at the gas valve before adjusting the pressure regulator.
Pressure Regulator Adjustment
Record the initial manifold pressure in inches of water column.
Is the manifold pressure within the acceptable range for natural gas (3.5 inches water column) or propane gas (10 inches water column)?
Adjust the pressure regulator direction
Record the final manifold pressure after adjustment.
Is the final manifold pressure within plus or minus 3 inches water column of the target pressure?
Propane Gas Specific Instructions
2 Monthly Filter Replacement
WARNING: HIGH VOLTAGE
Disconnect all power sources before servicing
Verify power disconnection from all sources
Filter Maintenance
Is the filter permanent?
Clean the permanent filter if applicable
Replace the disposable filter if applicable
Was the filter replaced with the same type and size?
Post Maintenance
Burner Visual Check
Safety Warning
HIGH VOLTAGE: Electrical components are contained in both compartments. To avoid electrical shock, injury or death, do not remove any internal compartment covers or attempt any adjustment. Contact a qualified service agent at once if an abnormal flame appearance should develop.
Turn the furnace on at the thermostat
Wait a few minutes for any dislodged dust to settle
Check the burner flames for the following characteristics
Are the flames stable, quiet, soft and blue with slightly orange tips?
Do the flames extend directly outward from the burner ports without curling downward, floating or lifting off the ports?
Heating Performance Test
Preparation
Ensure all other gas appliances are turned off
Wait for at least fifteen minutes after the heating cycle has started
Gas Meter Reading
Clock the gas meter to determine the time for one complete revolution of the cubic foot dial
Enter the time in seconds for one complete revolution
BTU Input Calculation
Enter the number of cubic feet of gas consumed per hour
Enter the calorific value of the gas (BTU per cubic foot)
Access the parts list for your equipment in MaintainX.
Electronic Air Cleaner
GSAS
Electronic Air Cleaner
ASAS
Media Air Cleaner
GMU
Media Air Cleaner
AMU
Filter Cartridge
M0-1056
Electronic Air Cleaner
GSAS
Electronic Air Cleaner
ASAS
Media Air Cleaner
GMU
Media Air Cleaner
AMU
Filter Cartridge
M0-1056
Electronic Air Cleaner
GSAS
Electronic Air Cleaner
ASAS
Media Air Cleaner
GMU
Media Air Cleaner
AMU
Filter Cartridge
M0-1056
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX