The Genie Articulated Boom Lift Z-33/18 is a versatile and compact aerial work platform designed for efficient access in tight spaces. Known for its reliability and ease of use, this model is ideal for various applications in construction and maintenance, ensuring safety and productivity on the job site.
Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Genie Articulated Boom Lift Z-33/18
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
3 Monthly Boom Angle Sensor Test
- Test the Primary Boom Angle Sensor - SX-105 XC, SX-125 XC, SX-135 XC, SX-150 and SX-180
A properly functioning primary boom angle sensor is essential to safe machine operation. The ECM at the ground controls (TCON) monitors the position and angle of the primary boom using the signal from the primary boom angle sensor
The primary boom angle sensor signal is used to control the ramping of the primary boom, limiting the speed of the primary boom to 2.3 feet / 0.7 meters per second
Note: The turntable level sensor must be tested before starting this procedure. Refer to Maintenance Procedures, Test the Turntable Level Sensor
Note: A digital level will be required to perform this procedure
Note: A kit is available through Genie Product Support (Genie part number 58351). This kit includes a digital level with a magnetic base and cable harnesses
Note: A properly calibrated digital level is essential to proper machine calibration. Refer to the manufactures calibration information
Note: Use the following chart to identify the description of each LCD screen control button used in this procedure
Note: Perform this procedure with the booms in the fully stowed position and the axles fully extended
3 Monthly Safety Envelope Limit Switch Test
- Test the Safety Envelope Limit Switches, Z-135/70, ZX-135/70, SX-105 XC, SX-125 XC, SX-135 XC, SX-150 and SX-180 Models
Testing the machine envelope safety limit switches is critical to safe machine operation. If the boom is allowed to operate when a safety switch is not functioning correctly, the machine stability could be compromised and may tip over
Note: Perform this procedure with the boom in the stowed position
Note: Perform this procedure with the axles extended
Note: Two people will be required to perform this procedure
Note: Use the following chart to identify the description of each LCD screen control button used in this procedure
Z-135/70 and ZX-135/70 Models:
Secondary Boom #1 Retracted Safety Limit Switch, LSS1RS
1. Working at the platform end of the turntable, support and secure the lower turntable riser end cover to a suitable lifting device
3 Monthly Secondary Boom Angle Sensor Test
- Test Secondary Boom Angle Sensor - Z-135/70 and ZX-135/70
A properly functioning secondary boom angle sensor is essential to safe machine operation. The ECM at the ground controls (TCON) monitors the position and angle of the secondary boom using the signal from the secondary boom angle sensor
The secondary boom angle sensor signal is used to control the ramping of the secondary boom
Note:The turntable level sensor must be tested before starting this procedure. Refer to Maintenance Procedure, Test the Turntable Level Sensor
Note: A digital level will be required to perform this procedure
Note: A kit is available through Genie Product Support (Genie part number 58351). This kit includes a digital level with a magnetic base and cable harnesses
Note: A properly calibrated digital level is essential to proper machine calibration. Refer to the manufactures calibration information
Note: Use the following chart to identify the description of each LCD screen control button used in this procedure
1. Turn the key switch to ground control and pull out the red Emergency Stop button to the on position at both ground and platform controls
3 Monthly Hydraulic Filters Inspection
- Inspect the Hydraulic Filters
Note: There are four types of hydraulic filters: tank return filter, medium pressure filter, high pressure filter and drive motor case drain filter. The quantity and type of filter(s) may vary by model
Models with Filter Condition Indicator:
1. Start the engine from the ground controls
2. Set the engine idle to high rpm (rabbit symbol)
3. Visually inspect the filter condition indicator
• Result: The filter condition indicator is operating in the green area
• Result: The filter condition indicator is operating in the red area. This indicates that the hydraulic filter is being bypassed and the filter should be replaced. Refer to Maintenance Procedure, Replace the Hydraulic Filters
Models without Filter Condition Indicator:
1 Daily Deutz Engine Maintanance
- Check / clean the oil cooler and cooling fins - Deutz D2011 and D436 Models
- Replace Engine oil and filter
- Replace Air filter
- Check/adjust Valve clearance - Test/add Engine coolant
- Inspect Air intake pipes
- Inspect V-belts
- Replace Fuel filter / separator;
Access the parts list for your equipment in MaintainX.
Digital Protractor
58377
Digital Level Kit
58351
O-ring Field Service Kit
49612
Digital Protractor
58377
Digital Level Kit
58351
O-ring Field Service Kit
49612
Digital Protractor
58377
Digital Level Kit
58351
O-ring Field Service Kit
49612
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX