MaintainX, an Autodesk company
EnterprisePricing
Frick

Frick Compressor Unit RWB II-60

Need answers fast?
Explore the manual using AI.

Frick Compressor Unit RWB II-60
Frick Compressor Unit RWB II-60

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Frick Compressor Unit RWB II-60

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Frick Compressor Unit RWB II-60

Frick Compressor Unit RWB II-60

Create an account to install this asset package.

Maintenance Plans for Frick Compressor Unit Model RWB II-60

Integrate maintenance plans directly into your work orders in MaintainX.

30000 Hourly Coalescer Maintenance

Check mark

Maintenance Schedule

Check mark

Replace Coalescers at specified hours of operation

Check mark

Change the oil when changing the coalescer filter element(s)

Check mark

Change cartridges in oil filters

Check mark

Remove and clean applicable strainer elements

Check mark

Ensure only Frick filter elements are used to avoid warranty issues

Check mark

Refer to the Coalescer Filter Element(s) procedure in the manual for detailed replacement steps

Run this procedureArrow right

Oil Cooler Chemical Cleaning

Check mark

Water-Cooled Oil Cooling

Check mark

Prepare a 3% solution of Phosphoric or Oxalic Acid

Check mark

Ensure the cleaning solution is suitable for stainless steel

Check mark

Back flush the oil cooler with the cleaning solution for 30 minutes

Check mark

Rinse the heat exchanger with fresh water

Run this procedureArrow right

Compressor Unit Storage Maintenance

Check mark

Holding Charge and Storage

Check mark

Ensure the nitrogen charge is safely released before entering the unit

Check mark

Remove holding charge shipping gauges before pressure testing and refrigerant charging

Check mark

Store units in a clean, dry location to prevent corrosion damage

Check mark

Consider proper care for solid-state components of the microprocessor

Check mark

Has the nitrogen charge been checked for units stored over two months?

Run this procedureArrow right

Cooling Water Quality Check

Check mark

Water-Cooled Oil Cooling

Check mark

Ensure all parts are in place for the closed-loop system

Check mark

Measure the pH level of the cooling water

Check mark

Is the pH level between 6.0 and 7.4?

Check mark

Describe any issues with the cooling water or closed-loop fluids

Run this procedureArrow right

Initial Compressor Unit Start-Up Check

Check mark

Initial Start-Up Procedure

Check mark

Is the start-up supervised by a Johnson Controls-Frick authorized representative?

Check mark

Ensure prestart check is accomplished as per the FORMS section

Check mark

Is there an adequate refrigerant load available for testing?

Check mark

Compressor Operation Check

Check mark

Enter the compressor speed

Check mark

Enter the discharge pressure

Check mark

Is the compressor running at the proper speed and discharge pressure?

Check mark

Motor Bearings Preparation

Run this procedureArrow right

Parts for Frick Compressor Unit RWB II-60

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

Cable, Belden, For RS-422 Communications

9829

Cable, Belden, For RS-485 Up To 2000 Feet (600 Meters) Total Cable Length

9841

Optical Isolation Kit, Frick, One Kit Is Required Per Comm Port

639C0133G01

Cable, Belden, For RS-422 Communications

9829

Cable, Belden, For RS-485 Up To 2000 Feet (600 Meters) Total Cable Length

9841

Optical Isolation Kit, Frick, One Kit Is Required Per Comm Port

639C0133G01

Cable, Belden, For RS-422 Communications

9829

Cable, Belden, For RS-485 Up To 2000 Feet (600 Meters) Total Cable Length

9841

Optical Isolation Kit, Frick, One Kit Is Required Per Comm Port

639C0133G01

Unlock
efficiency with MaintainX Assist

MaintainX Assist is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Frick

Explore Other Assets