FG Wilson Generator Set P1250P3
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
Racor Pre-Filter Maintenance
Preparation
Ensure fuel supply source is identified
Fuel Supply from the Base Tank
Remove T-handle and lid from the top of the unit
Screw T-handle into centre tube finger tight
Fill the assembly with clean fuel to just above the top of the element
Lubricate the lid gasket and T-handle O-ring with clean fuel
Replace the lid, seat the gasket correctly, and tighten the T-handle
Operate the priming switch for 2 minutes (if fitted)
1 Monthly Operational Load Check
Pre-Operation Checks
Ensure generator set is not running on load
Inspect generator set for any visible damage or leaks
Operational Load Check
Record initial generator load percentage
Set generator load to at least 50%
Run generator set for 1 to 2 hours
Post-Operation Checks
Record final generator load percentage
Pre-Start Inspection
Visual Inspection
Check for loose fastenings, worn belts, or loose connections
Ensure fan and exhaust guards are correctly positioned and secure
Wipe clean all filler caps before servicing or topping up fluids
Check for any type of leak and clean away fluid
Remove accumulated grease or oil on the engine
Ensure coolant pipes are fitted correctly and secure
Fluid and Fuel Checks
Check the engine oil level and replenish as necessary
500 Hourly / 1 Yearly Control System Safety Check
Repeat all daily pre-start checks
Check all control system safety devices by electrically simulating faults
Clean all battery cap vents
Tighten all exhaust connections
Tighten all electrical connections
Engine Start and Instrument Panel Observation
Start the engine
Observe the instrument panel to ensure that all gauges and meters are operating properly
Consult your local dealer for maintenance guidelines specific to your engine
DEF Tank Storage Maintenance
Pre-storage Engine and Exhaust Preparation
Allow engine to perform DEF purge for 2 minutes after stopping
Cap the exhaust outlet of the aftertreatment
DEF Tank and Line Preparation
Ensure normal engine shutdown
Fill the tank with DEF meeting ISO 22241-1 requirements
Reconnect all DEF lines and electrical connections to prevent DEF crystals from forming
Ensure the DEF filler cap is correctly installed
DEF Storage Duration Limits
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX