

Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

York Centrifugal Chiller YKJPJSP95CEGS
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
3 Monthly Chliller Maintenance
7.1.4 Every 3 Months
Perform chemical analysis of oil
Leak test the unit
Were any leaks found?
Repair any leaks found immediately
7.4.2 Leak Testing
Charge the system
Perform leak test with R134a compatible leak detector
Are all joints tight?
1 Yearly Compressor Maintenance
7.1.6 Annually (more often if necessary)
Drain and replace the oil in the compressor oil sump
7.3 Oil Charge
Verify the nominal oil charge for the compressor is 75.7 litres of York 'K' oil
Ensure only York 'K' refrigeration oil is used in the centrifugal compressor
Keep oil tightly capped until used to prevent moisture absorption
7.3.1 Oil Charging Procedure
Shut down the unit
Prepare the oil charging pump and connect to the oil charging valve
1 Weekly Refrigerant Charge Check
7.1.3 Weekly
Check the refrigerant charge (See Refrigerant Charge Checking)
7.4.1 Checking The Refrigerant Charge
Record the refrigerant level after initial charging
Is the refrigerant level visible in the sight glass?
Ensure the system is shut down before checking and trimming the refrigerant charge
Verify that at least 4 hours have passed since the compressor and water pumps were stopped
Have the pressure and temperature equalised between the condenser and evaporator?
Chiller Refrigerant Maintenance
7.4.4 Refrigerant Charging
Remove refrigerant charge when opening any part of the refrigerant system for repairs.
Isolate refrigerant in either the condenser or evaporator/compressor if equipped with optional valves.
Add only refrigerant vapour to the system until pressure is above freezing point of evaporator liquid.
Ensure system pressure is above 58.9 kPa for R134a to prevent freezing.
Prevent moisture laden air from entering the system during charging.
Make up a suitable charging connection from new copper tubing.
Purge the charging connection each time a new container of refrigerant is connected.
Change containers quickly to minimise refrigerant loss.
1 Yearly Heat Exchangers Maintenance
7.1.6 Annually (more often if necessary)
Inspect and clean components
7.5 Condenser and Evaporator
Check for common water issues
Is water treatment necessary?
Recommendations for water treatment
7.5.1 Chemical Water Treatment
Has a chemical analysis of the water been conducted?
Water treatment expert consultation notes
Access the parts list for your equipment in MaintainX.
Heat Conductive Compound
013-00890-000
Oil Charging Pump
070-10654
Heat Conductive Compound
013-00890-000
Oil Charging Pump
070-10654
Heat Conductive Compound
013-00890-000
Oil Charging Pump
070-10654
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX













