Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Wilo Pump TOP-S65/15
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
Pump Leak Check
7.1 Installation
Check for leaks after installation
Periodically verify all connections remain leak-free during operation
Describe any leakages of hazardous fluids and actions taken to remove them
Condensate Drain Check
7.1 Installation / 7.1.3 Insulation
Verify the following conditions for outdoor installations and cooling/air-conditioning systems
Check that condensate drain openings are clear and unobstructed
Verify that insulation has not been applied beyond the motor separation joint
Rotation Direction Check
8.2 Rotation direction monitoring
Is the pump a three-phase pump?
Briefly switch the pump on to check the direction of rotation
Does the light on the terminal box light up green?
Is the direction of rotation correct according to the arrow on the rating plate?
If the direction of rotation is incorrect
Electrically isolate the pump
Interchange 2 phases in the terminal box
Restart the pump
Pump Maintenance
8.1 Filling and Venting
Switch off the pump
Close the check valve on the pressure side
Protect electrical parts from any escaping water
Carefully open the venting screw using a suitable tool
Is the necessary inlet pressure present at the suction side of the pump?
Carefully push back the motor shaft with a screwdriver several times
Wait for 15 to 30 seconds before screwing the venting screw back in
Screw the venting screw back in
Pump Startup Check
8 Commissioning
Verify installation and connection
Is the sealing screw including the flat gasket in place?
Prime and vent the unit correctly
Ensure automatic venting of the pump rotor compartment after a short operating period
Is dry running limited to short periods?
Ensure no unauthorized removal of components
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX