Wilo Pump TOP-S50/15
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
Condensate Drain Check
7.1 Installation / 7.1.3 Insulation
Verify the following conditions for outdoor installations and cooling/air-conditioning systems
Check that condensate drain openings are clear and unobstructed
Verify that insulation has not been applied beyond the motor separation joint
Pump Maintenance
8.1 Filling and Venting
Switch off the pump
Close the check valve on the pressure side
Protect electrical parts from any escaping water
Carefully open the venting screw using a suitable tool
Is the necessary inlet pressure present at the suction side of the pump?
Carefully push back the motor shaft with a screwdriver several times
Wait for 15 to 30 seconds before screwing the venting screw back in
Screw the venting screw back in
Motor Maintenance
9.1 Dismantling/installation of the motor
Read the chapters 'Dismantling/installation of the motor' and 'Decommissioning' before maintenance
Comply with safety instructions in chapters 2.6, 7, and 8
Close existing check valves on both sides of the pump
Allow the pump to cool to room temperature
Drain the isolated branch of the system
Drain the entire system if no check valves are fitted
Observe manufacturer's information and safety data sheets on possible additives
Comply with national regulations for accident prevention to avoid motor falling injuries
Rotation Direction Check
8.2 Rotation direction monitoring
Is the direction of rotation light green when the pump is briefly switched on?
If the direction of rotation is incorrect, has the pump been electrically isolated and two phases interchanged in the terminal box?
Restart the pump after interchanging the phases.
Does the motor's direction of rotation correspond to the direction of rotation arrow on the rating plate?
Frequency Converter Check
Frequency converter operation
Check the type of output filter used
Measure the rate of voltage rise (du/dt)
Is the rate of voltage rise within the limit (du/dt < 500 V/μs)?
Measure the voltage spikes (û)
Are the voltage spikes within the limit (û < 650 V)?
Measure the minimum voltage at connection terminals (Umin)
Is the minimum voltage at connection terminals above 150 V?
Measure the minimum frequency at connection terminals (fmin)
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX