Wilo Pump MAXO 1.25 x 3 – 20
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
Motor Assembling
Shutdown Precautions
Avoid flow in the pump during dismantling/installation work!
Close the existing shut-off valves in front of and behind the pump!
If no shut-off valves are fitted, drain the system!
Motor Installation
Tighten motor fastening screws diagonally. Observe the tightening torques!
Insert sensor cable into the electronic module interface.
Is the electronic module separated from the motor for access to the screws on the motor flange?
For twin-head pumps, is the twin-head pump cable loosened or inserted?
Electronic Module Assembling
Shutdown Precautions
Avoid flow in the pump during dismantling/installation work
Close the existing shut-off valves in front of and behind the pump
Drain the system if no shut-off valves are fitted
Do not place any objects in the contact area of the motor
Safety Warnings
Ensure correct assignment of pump/electronic module during replacement
Disassembling the Electronic Module
Loosen handle grip of the Wilo-Connector using a screwdriver and pull out socket
Electronic Module Disassembling
Shutdown Precautions
Ensure generator or turbine is not operating during pump flow
Close shut-off valves in front of and behind the pump
Drain the system if no shut-off valves are fitted
Ensure no objects are placed in the contact area of the motor
Module Replacement Precautions
Ensure correct assignment of pump/electronic module during replacement
Disassembling the Electronic Module
Loosen handle grip of the Wilo-Connector using a screwdriver and pull out socket
Housing Sensor Disassembling
Shutdown Precautions
Allow the pump to cool down before commencing any work
Close shut-off device or drain unit
Follow manufacturer’s instructions and safety data sheets for additives
Sensor Disassembly
Dismantle the two-part thermal insulation from the pump housing of single pumps
Pull sensor socket from sensor
Loosen screws of the fixing plate
Pull out sensor
Housing Sensor Assembling
Shutdown Precautions
Allow the pump to cool down before commencing any work
Close shut-off device or drain unit
Follow the manufacturer’s instructions and safety data sheets for possible additives in the system
Dismantling the Sensor
Dismantle the two-part thermal insulation from the pump housing of single pumps
Pull sensor socket from sensor
Loosen screws of the fixing plate
Pull out sensor
MaintainX Assist is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX