MaintainX Asset Hub logo
EnterprisePricing
Wilo

Wilo Pump TOP-S25/5

Need answers fast?
Explore the manual using AI.

Wilo Pump TOP-S25/5
Wilo Pump TOP-S25/5

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Wilo Pump TOP-S25/5

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Wilo Pump TOP-S25/5

Wilo Pump TOP-S25/5

Create an account to install this asset package.

Maintenance Plans for Wilo Pump Model TOP-S25/5

Integrate maintenance plans directly into your work orders in MaintainX.

Motor Protection System Check

Check mark

Motor Protection System Verification

Check mark

Verify terminal box type and corresponding protection mechanism

Check mark

Record the maximum current from the rating plate

Check mark

Does the thermal tripping setting correspond to the maximum current?

Check mark

Is the Wilo tripping unit SK 602(N)/SK 622(N) present?

Check mark

Is the thermal winding contact (WSK) connected to a motor protection system?

Check mark

Reset Procedures

Check mark

Perform reset based on terminal box type

Run this procedureArrow right

Pump Maintenance

Check mark

8.1 Filling and Venting

Check mark

Switch off the pump

Check mark

Close the check valve on the pressure side

Check mark

Protect electrical parts from any escaping water

Check mark

Carefully open the venting screw using a suitable tool

Check mark

Ensure the necessary inlet pressure is present at the suction side of the pump

Check mark

Carefully push back the motor shaft with a screwdriver several times

Check mark

Wait for 15 to 30 seconds before screwing the venting screw back in

Check mark

Screw the venting screw back in

Run this procedureArrow right

Electrical Connection Check

Check mark

Pre-Work Safety Measures

Check mark

Ensure all poles of the power supply are disconnected before working on the pump

Check mark

Wait 5 minutes before commencing work on the module for 1~ systems to allow voltages to dissipate

Check mark

Connection Verification

Check mark

Verify all connections (including potential-free contacts) are voltage-free

Check mark

Is the module/terminal box undamaged?

Check mark

Does the current type and voltage of the mains connection correspond to the specifications on the rating plate?

Check mark

Connection Requirements

Check mark

Ensure electrical connection is via a fixed connection line with a connector device or an all-pole switch with a contact opening width of at least 3 mm

Run this procedureArrow right

Thermal Insulation Shell Inspection

Check mark

7.1.3 Insulation of the pump in cooling/air-conditioning systems

Check mark

Verify the application of the insulation

Check mark

Check if the two half-shells of the thermal insulation are correctly fitted and guide pins are engaged in the opposite holes

Check mark

For cooling/air-conditioning systems, verify that commercially-available diffusion-proof thermal insulation materials are used instead of the supplied shells

Run this procedureArrow right

Rotation Direction Check

Check mark

8.2 Rotation direction monitoring

Check mark

Verify the following conditions for three-phase pumps

Check mark

Briefly switch the pump on to check the direction of rotation

Check mark

Is the direction of rotation correct (green light on)?

Check mark

Does the motor's direction of rotation correspond to the direction of rotation arrow on the rating plate?

Check mark

If the direction of rotation is incorrect

Check mark

Electrically isolate the pump

Check mark

Interchange 2 phases in the terminal box

Check mark

Restart the pump

Run this procedureArrow right

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Wilo

Explore Other Assets