Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Wilo Pump TOP-S25/5
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
Motor Protection System Check
Motor Protection System Verification
Verify terminal box type and corresponding protection mechanism
Record the maximum current from the rating plate
Does the thermal tripping setting correspond to the maximum current?
Is the Wilo tripping unit SK 602(N)/SK 622(N) present?
Is the thermal winding contact (WSK) connected to a motor protection system?
Reset Procedures
Perform reset based on terminal box type
Pump Maintenance
8.1 Filling and Venting
Switch off the pump
Close the check valve on the pressure side
Protect electrical parts from any escaping water
Carefully open the venting screw using a suitable tool
Ensure the necessary inlet pressure is present at the suction side of the pump
Carefully push back the motor shaft with a screwdriver several times
Wait for 15 to 30 seconds before screwing the venting screw back in
Screw the venting screw back in
Electrical Connection Check
Pre-Work Safety Measures
Ensure all poles of the power supply are disconnected before working on the pump
Wait 5 minutes before commencing work on the module for 1~ systems to allow voltages to dissipate
Connection Verification
Verify all connections (including potential-free contacts) are voltage-free
Is the module/terminal box undamaged?
Does the current type and voltage of the mains connection correspond to the specifications on the rating plate?
Connection Requirements
Ensure electrical connection is via a fixed connection line with a connector device or an all-pole switch with a contact opening width of at least 3 mm
Thermal Insulation Shell Inspection
7.1.3 Insulation of the pump in cooling/air-conditioning systems
Verify the application of the insulation
Check if the two half-shells of the thermal insulation are correctly fitted and guide pins are engaged in the opposite holes
For cooling/air-conditioning systems, verify that commercially-available diffusion-proof thermal insulation materials are used instead of the supplied shells
Rotation Direction Check
8.2 Rotation direction monitoring
Verify the following conditions for three-phase pumps
Briefly switch the pump on to check the direction of rotation
Is the direction of rotation correct (green light on)?
Does the motor's direction of rotation correspond to the direction of rotation arrow on the rating plate?
If the direction of rotation is incorrect
Electrically isolate the pump
Interchange 2 phases in the terminal box
Restart the pump
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX