MaintainX Logo
EnterprisePricing
Sullair

Sullair Air Dryer SRHT 30 AC

Need answers fast?
Explore the manual using AI.

Sullair Air Dryer SRHT 30 AC
Sullair Air Dryer SRHT 30 AC

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Sullair Air Dryer SRHT 30 AC

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Sullair Air Dryer SRHT 30 AC

Sullair Air Dryer SRHT 30 AC

Create an account to install this asset package.

Maintenance Plans for Sullair Air Dryer Model SRHT 30 AC

Integrate maintenance plans directly into your work orders in MaintainX.

200 Hourly/1 Monthly Air Dryer Maintenance

Check mark

Danger! Compressed air! Risk of serious injury or death through contact with quickly or suddenly escaping compressed air or through bursting and/or unsecured plant components. Compressed air is a highly dangerous energy source.

Check mark

Never work on the dryer when the system is under pressure. Never direct the compressed-air outlet or condensate drain hoses at persons.

Check mark

The user is responsible for the proper maintenance of the dryer. Non-observance of the instructions in the 'Installation' and 'Maintenance, troubleshooting, spare parts and dismantling' chapters leads to the expiration of the guarantee. Improper maintenance may result in dangerous situations for the personnel and/or the device.

Check mark

Danger! Supply voltage! Contact with non-insulated parts carrying supply voltage involves the risk of an electric shock resulting in injuries and death.

Check mark

Only qualified and skilled personnel are authorised to run electrically-operated devices. Prior to undertaking maintenance measures at the device, the following requirements must be met: Make sure that the power supply is switched off and that the device is off and marked for maintenance measures. Please also ensure that the power supply cannot be re-established during the works.

Check mark

Prior to carrying out maintenance works at the dryer, switch it off and wait for at least 30 minutes.

Check mark

Caution! Hot surfaces! During operation, several components can reach surface temperatures of more than 140°F (60°C). There is the risk of burns.

Check mark

All components concerned are installed inside of the closed housing. The housing must only be opened by certified skilled personnel.

Check mark

Some components can reach high temperatures during operation. Avoid any contact until the system or the component has cooled down.

Run this procedureArrow right

1 Daily Air Dryer Maintenance

Check mark

Danger! Compressed air! Risk of serious injury or death through contact with quickly or suddenly escaping compressed air or through bursting and/or unsecured plant components. Compressed air is a highly dangerous energy source. Never work on the dryer when the system is under pressure. Never direct the compressed-air outlet or condensate drain hoses at persons.

Check mark

The user is responsible for the proper maintenance of the dryer. Non-observance of the instructions in the 'Installation' and 'Maintenance, troubleshooting, spare parts and dismantling' chapters leads to the expiration of the guarantee. Improper maintenance may result in dangerous situations for the personnel and/or the device.

Check mark

Danger! Supply voltage! Contact with non-insulated parts carrying supply voltage involves the risk of an electric shock resulting in injuries and death. Only qualified and skilled personnel are authorised to run electrically-operated devices.

Check mark

Prior to undertaking maintenance measures at the device, the following requirements must be met: Make sure that the power supply is switched off and that the device is off and marked for maintenance measures. Please also ensure that the power supply cannot be re-established during the works. Prior to carrying out maintenance works at the dryer, switch it off and wait for at least 30 minutes.

Check mark

Caution! Hot surfaces! During operation, several components can reach surface temperatures of more than 140°F (60°C). There is the risk of burns. All components concerned are installed inside of the closed housing. The housing must only be opened by certified skilled personnel. Some components can reach high temperatures during operation. Avoid any contact until the system or the component has cooled down.

Check mark

Check whether the dew point indicated on the electronics is correct.

Check mark

Ensure that the condensate drain system functions properly.

Check mark

Make sure that the condenser is clean.

Run this procedureArrow right

8000 Hourly Air Dryer Maintenance

Check mark

Warning: Compressed air! Risk of serious injury or death through contact with quickly or suddenly escaping compressed air or through bursting and/or unsecured plant components. Compressed air is a highly dangerous energy source.

Check mark

Warning: Supply voltage! Contact with non-insulated parts carrying supply voltage involves the risk of an electric shock resulting in injuries and death.

Check mark

Caution: Hot surfaces! During operation, several components can reach surface temperatures of more than 140°F (60°C). There is the risk of burns.

Check mark

System is not under pressure

Check mark

Power supply is switched off and the device is off and marked for maintenance measures

Check mark

Waited for at least 30 minutes after switching off the dryer

Check mark

System or the component has cooled down

Check mark

SULLIMAX Service Unit replaced

Check mark

Sign off on the 8000 Hourly Air Dryer Maintenance

Run this procedureArrow right

1000 Hourly/1 Yearly Air Dryer Maintenance

Check mark

Danger! Compressed air! Risk of serious injury or death through contact with quickly or suddenly escaping compressed air or through bursting and/or unsecured plant components. Compressed air is a highly dangerous energy source.

Check mark

Never work on the dryer when the system is under pressure. Never direct the compressed-air outlet or condensate drain hoses at persons.

Check mark

The user is responsible for the proper maintenance of the dryer. Non-observance of the instructions in the 'Installation' and 'Maintenance, troubleshooting, spare parts and dismantling' chapters leads to the expiration of the guarantee. Improper maintenance may result in dangerous situations for the personnel and/or the device.

Check mark

Danger! Supply voltage! Contact with non-insulated parts carrying supply voltage involves the risk of an electric shock resulting in injuries and death.

Check mark

Only qualified and skilled personnel are authorised to run electrically-operated devices. Prior to undertaking maintenance measures at the device, the following requirements must be met: Make sure that the power supply is switched off and that the device is off and marked for maintenance measures. Please also ensure that the power supply cannot be re-established during the works.

Check mark

Prior to carrying out maintenance works at the dryer, switch it off and wait for at least 30 minutes.

Check mark

Caution! Hot surfaces! During operation, several components can reach surface temperatures of more than 140°F (60°C). There is the risk of burns.

Check mark

All components concerned are installed inside of the closed housing. The housing must only be opened by certified skilled personnel.

Check mark

Some components can reach high temperatures during operation. Avoid any contact until the system or the component has cooled down.

Run this procedureArrow right

Parts for Sullair Air Dryer SRHT 30 AC

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

Complete Heat Exchanger

02250249-327

Aftercooler Safety Thermo Switch

02250248-595

Pressure Switch

02250248-092

Compressor

02250247-958

Hot Gas By-Pass Valve

02250248-017

Complete Heat Exchanger

02250249-327

Aftercooler Safety Thermo Switch

02250248-595

Pressure Switch

02250248-092

Compressor

02250247-958

Hot Gas By-Pass Valve

02250248-017

Complete Heat Exchanger

02250249-327

Aftercooler Safety Thermo Switch

02250248-595

Pressure Switch

02250248-092

Compressor

02250247-958

Hot Gas By-Pass Valve

02250248-017

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Sullair

Explore Other Assets