MaintainX Asset Hub logo
EnterprisePricing
SSCOR

SSCOR Duet Portable Aspirator 2314BV-230

Need answers fast?
Explore the manual using AI.

SSCOR Duet Portable Aspirator 2314BV-230
SSCOR Duet Portable Aspirator 2314BV-230

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for SSCOR Duet Portable Aspirator 2314BV-230

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

SSCOR Duet Portable Aspirator 2314BV-230

SSCOR Duet Portable Aspirator 2314BV-230

Create an account to install this asset package.

Maintenance Plans for SSCOR Duet Portable Aspirator Model 2314BV-230

Integrate maintenance plans directly into your work orders in MaintainX.

Battery Testing

Check mark

Check that the power source connected LED and the green battery condition LED are lit

Check mark

Remove the power cord and run the unit from its internal DC battery

Check mark

Check for vacuum by occluding the patient tube and set the vacuum regulator to the maximum vacuum setting

Check mark

Observe the regulator gauge

Check mark

Enter the vacuum reading after 3 seconds

Check mark

Is the vacuum reading ≥ -525mmHg?

Check mark

Allow the unit to run for 15 minutes on DC power

Check mark

Did the unit stop or slow during the 15 minutes?

Check mark

Did the battery condition indicators begin to blink?

Run this procedureArrow right

Duet Portable Aspirator Cleaning

Check mark

Sanitation

Check mark

Discard single use items

Check mark

Clean with mild detergent

Check mark

Disinfect with mild disinfectant (e.g., 10 to 1 bleach)

Check mark

Rinse with clear water to remove residue

Check mark

Exhaust Filter Maintenance

Check mark

Is the exhaust filter soiled?

Check mark

Remove screws holding the filter door in place

Check mark

Replace soiled filter with new filter (SSCOR part number 90160)

Run this procedureArrow right

Duet Portable Aspirator Maintenance

Check mark

Battery Maintenance

Check mark

Keep batteries on continuous charge when not in use

Check mark

Regular Testing

Check mark

Test the SSCOR aspirator at regular intervals

Check mark

Cleaning and Readiness

Check mark

Ensure the SSCOR aspirator is clean and ready for use

Check mark

Vacuum Line Check

Check mark

Was there an excessive quantity of fluids produced during the procedure?

Check mark

Check the vacuum line for evidence of moisture

Run this procedureArrow right

1 Yearly Duet Portable Aspirator Maintenance

Check mark

Canister Expiration Check

Check mark

Is the canister expiration date valid?

Check mark

Battery Health Test

Check mark

Charge the device for at least 8 hours before testing.

Check mark

Is the battery condition LED green when fully charged?

Check mark

Ensure tubing is connected to the canister and lid is secure.

Check mark

Unplug the device and turn it on to start the test.

Check mark

Record the run time of the device in minutes.

Check mark

Did the device run for at least 41 minutes?

Run this procedureArrow right

Parts for SSCOR Duet Portable Aspirator 2314BV-230

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

Rechargeable Sealed Lead Acid.

80635

Collection Canister (13) 1200Cc/Ml

48041

Vinyl Tubing 9/32”ID x 72”L (7.1Mm ID x 182.88 Cm L)

43200

Suction Tip HI-D® “Big Stick®”

44241C

Filter

90160

Rechargeable Sealed Lead Acid.

80635

Collection Canister (13) 1200Cc/Ml

48041

Vinyl Tubing 9/32”ID x 72”L (7.1Mm ID x 182.88 Cm L)

43200

Suction Tip HI-D® “Big Stick®”

44241C

Filter

90160

Rechargeable Sealed Lead Acid.

80635

Collection Canister (13) 1200Cc/Ml

48041

Vinyl Tubing 9/32”ID x 72”L (7.1Mm ID x 182.88 Cm L)

43200

Suction Tip HI-D® “Big Stick®”

44241C

Filter

90160

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from SSCOR

Explore Other Assets