Schneider Electric Circuit Breaker MTZ1-1600-H3
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
MCH Gear Motor Check
Preparation
Remove the MCH gear motor power supply
Perform an opening/closing/opening cycle to discharge the mechanism
Electrical Continuity Check
Check electrical continuity and non-continuity
Mechanism Charging
Manually charge the mechanism
Reconnect the MCH gear motor power supply
Confirm the device closes and the mechanism is automatically charged
Functional Check
Mechanism Charging
Manually charge the mechanism by pulling the spring charging handle down
Device Closing Check
Close the device
Check the closing of the device in the different control modes and means designed for the application
Device Opening Check
Open the device
Check the opening of the device in the different control modes and means designed for the application
Communication Network Testing
Setup and Connection
Connect a PC running Ecoreach software using an RJ45 cable to the communication network
Device Selection and Testing
Select devices to be tested from the list of communicating devices in Ecoreach software
Click Run test to test all selected devices
Results and Reporting
Were the results displayed at the end of the test?
Generate the communication test report with Ecoreach software
Save or print the project report as needed
Micrologic X Ready LED Status Check
Power the Micrologic X control unit
Check the Micrologic X Ready LED status
Refer to chapter Critical Cases if the Ready LED is not flashing green
M2C Programmable Contacts and IO Module Check
Connect PC to Micrologic X control unit
Force state of M2C programmable contacts
Force state of digital inputs and outputs
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX