MaintainX Asset Hub logo
EnterprisePricing
Pompetravaini

Pompetravaini Pump TC40-125

Need answers fast?
Explore the manual using AI.

Pompetravaini Pump TC40-125
Pompetravaini Pump TC40-125

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Pompetravaini Pump TC40-125

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Pompetravaini Pump TC40-125

Pompetravaini Pump TC40-125

Create an account to install this asset package.

Maintenance Plans for Pompetravaini Pump Model TC40-125

Integrate maintenance plans directly into your work orders in MaintainX.

17500 Hourly Bearing Replacement

Check mark

Safety Precautions

Check mark

Ensure the pump is completely stopped before handling the unit.

Check mark

Drain the pump or close the pipes using a valve to prevent sudden rotation.

Check mark

Wait for the pump to cool to avoid contact with high temperature surfaces.

Check mark

Disconnect the power supply and any other connections before starting maintenance.

Check mark

Ensure power supply is restored only by the maintenance operator.

Check mark

Ensure the presence of at least two operators during maintenance.

Check mark

Inform the foreman that maintenance is in progress.

Check mark

Use appropriate protective devices.

Run this procedureArrow right

4000 Hourly Oil Replacement

Check mark

Oil Replacement Procedure

Check mark

Pour oil directly into the cruet

Check mark

Ensure oil is not poured into the elbow of the oil-filler or bearing frame plug

Check mark

Oil Change Frequency

Check mark

Select the oil change frequency based on operating conditions

Check mark

Bearing Temperature Check

Check mark

Record the bearing temperature

Check mark

Is the bearing temperature below 85°C/185°F?

Check mark

Oil pH and Viscosity Check

Run this procedureArrow right

4000 Hourly Seal Check

Check mark

Seal Inspection

Check mark

Record the total working hours of the mechanical seal

Check mark

Is the mechanical seal within the acceptable life span of 4000 hours?

Check mark

Inspect the wear of seal faces

Check mark

Seal Replacement

Check mark

Was the mechanical seal replaced?

Check mark

Check the condition of the shaft sleeve if present

Check mark

Is the shaft sleeve surface damaged or doubtful?

Check mark

Replace the shaft sleeve if necessary

Run this procedureArrow right

Initial 50 Hours Oil Replacement

Check mark

Preparation

Check mark

Ensure the pump is turned off and cooled down

Check mark

Gather necessary tools and materials (oil, oil-cruet, etc.)

Check mark

Oil Draining

Check mark

Remove the vent plug of the bearing frame

Check mark

Dispose of the exhausted oil following current regulations

Check mark

Oil Filling

Check mark

Upset the oil-cruet

Check mark

Pour oil into the bearing frame through the hole of the plug until oil is visible in the oil-filler elbow

Run this procedureArrow right

Initial 6 Months Lubricant Replacement

Check mark

Long Term Storage Inspection

Check mark

Ensure the following actions are considered

Check mark

Lubricant Replacement

Check mark

Replace the lubricant completely

Check mark

Bearing Inspection

Check mark

Inspect the bearings

Check mark

Were the bearings cleaned?

Check mark

O-rings and Gaskets Inspection

Check mark

Inspect O-rings and gaskets

Run this procedureArrow right

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Pompetravaini

Explore Other Assets