MaintainX Asset Hub logo
EnterprisePricing
Pompetravaini

Pompetravaini Pump TC25-200

Need answers fast?
Explore the manual using AI.

Pompetravaini Pump TC25-200
Pompetravaini Pump TC25-200

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Pompetravaini Pump TC25-200

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Pompetravaini Pump TC25-200

Pompetravaini Pump TC25-200

Create an account to install this asset package.

Maintenance Plans for Pompetravaini Pump Model TC25-200

Integrate maintenance plans directly into your work orders in MaintainX.

17500 Hourly Bearing Replacement

Check mark

Safety Precautions

Check mark

Ensure the pump is completely stopped before handling

Check mark

Drain the pump or close the pipes using a valve to prevent sudden rotation

Check mark

Wait for the pump to cool to avoid contact with high temperature surfaces

Check mark

Disconnect the power supply and any other connections

Check mark

Ensure power supply is restored only by the maintenance operator

Check mark

Ensure the presence of at least two operators during maintenance

Check mark

Inform the foreman that maintenance is in progress

Check mark

Use appropriate protective devices

Run this procedureArrow right

Initial 6 Months Lubricant Replacement

Check mark

Long Term Storage Inspection

Check mark

Ensure the following actions are considered

Check mark

Lubricant Replacement

Check mark

Replace the lubricant completely

Check mark

Bearing Inspection

Check mark

Inspect the bearings

Check mark

Were the bearings cleaned?

Check mark

O-rings and Gaskets Inspection

Check mark

Inspect O-rings and gaskets

Run this procedureArrow right

4000 Hourly Oil Replacement

Check mark

Oil Filling Instructions

Check mark

Pour oil directly into the cruet, not into the elbow of the oil-filler or bearing frame plug

Check mark

Oil Change Frequency

Check mark

Select the oil change frequency based on operating conditions

Check mark

Bearing Temperature Check

Check mark

Record the bearing temperature

Check mark

Is the bearing temperature within the normal range (below 85°C/185°F)?

Check mark

Oil pH and Viscosity Check

Check mark

Record the oil pH value

Run this procedureArrow right

1 Yearly Pump Check

Check mark

Instrument Readings

Check mark

Record the gauge readings

Check mark

Record the amp meter readings

Check mark

Record the flow meter readings

Check mark

Operational Check

Check mark

Is the pump operating without abnormal vibrations or noises?

Check mark

Check the alignment and conditions

Check mark

Auxiliary Supply Lines Check

Check mark

Check the flow in auxiliary supply lines

Run this procedureArrow right

2000 Hourly Bearing Maintenance

Check mark

Initial Inspection

Check mark

Verify pump series and bearing type

Check mark

Is the bearing sealed and pre-greased?

Check mark

Bearing Maintenance for Non-Sealed Bearings

Check mark

Clean the bearings carefully

Check mark

Apply new lubricating grease

Check mark

Ensure not to over lubricate the bearings

Check mark

Bearing Temperature Check

Check mark

Measure the bearing temperature

Run this procedureArrow right

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Pompetravaini

Explore Other Assets