

Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Mazak Vertical Machining Center Nexus 530C-II DM
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
Initial Vertical Machining Center Cleaning
Warning: Do not operate the machine before cleaning
Presence of rust preventive oil on slideways and other machine parts
Upload a photo of the machine before cleaning
Remove rust preventive oil with rag soaked with washing oil
Successful removal of rust preventive oil
Upload a photo of the machine after cleaning
Note: Take care to avoid entry of cleaning oil into the slideway surfaces passing the wiper
Sign off on the initial cleaning of the Vertical Machining Center
250 Hourly / 1 Monthly High-Pressure Coolant Line Filter Element Replacement
WARNING: Always switch off the main power disconnect switch and lock it before carrying out any maintenance work.
Maintenance of electrical equipment must be carried out by qualified licensed electrical engineers only.
When carrying out maintenance in high places, always use a suitable ladder or a service platform and always wear a helmet.
Do not start the machine until all of the covers removed for maintenance have been refitted.
Maintenance work should be carried out by qualified personnel in accordance with the instructions of the person in charge.
Use only the specified grades of hydraulic oil, lubricating oil, and grease or their equivalents.
Follow the instructions on the instruction plate concerning the brands of oil to be used, lubrication points, amount to be used, and oil change intervals.
Stop all machine operation before cleaning the machine or the surrounding area.
Stop the through-spindle coolant and after confirming that coolant does not flow, remove the drain plug to completely empty the filter by draining coolant.
1500 Hourly / 6 Monthly ATC Unit Hydraulic Oil Change
WARNING: Always switch off the main power disconnect switch and lock it before carrying out any maintenance work.
Maintenance of electrical equipment must be carried out by qualified licensed electrical engineers only.
When carrying out maintenance in high places, always use a suitable ladder or a service platform and always wear a helmet.
Do not start the machine until all of the covers removed for maintenance have been refitted.
Maintenance work should be carried out by qualified personnel in accordance with the instructions of the person in charge.
Use only the specified grades of hydraulic oil, lubricating oil, and grease or their equivalents.
Follow the instructions on the instruction plate concerning the brands of oil to be used, lubrication points, amount to be used, and oil change intervals.
Stop all machine operation before cleaning the machine or the surrounding area.
Shut off the power before changing the hydraulic oil.
1500 Hourly / 6 Monthly Grease Level Adjustment
WARNING:
- Always switch off the main power disconnect switch and lock it before carrying out any maintenance work. This will eliminate the possibility of the machinery being accidentally started by someone else.
- After the power has been switched off for a short while, check the voltage with a multimeter or similar instrument to make sure that there is no residual voltage. Also discharge the capacitors.
- Maintenance of electrical equipment must be carried out by qualified licensed electrical engineers only.
- Do not remove or modify limit switches, proximity switches, or other safety devices.
- When carrying out maintenance in high places, always use a suitable ladder or a service platform and always wear a helmet.
- Always switch off the main power disconnect switch and lock it before replacing bulbs or other electrical equipment, and use products with the same specifications as the original.
- Do not start the machine until all of the covers removed for maintenance have been refitted.
- Wipe up any water or oil spills immediately, and keep the maintenance area and the workplace clean and tidy at all times.
3000 Hourly / 1 Yearly Vertical Machining Center Maintenance
WARNING: Always switch off the main power disconnect switch and lock it before carrying out any maintenance work.
WARNING: Maintenance of electrical equipment must be carried out by qualified licensed electrical engineers only.
WARNING: When carrying out maintenance in high places, always use a suitable ladder or a service platform and always wear a helmet.
WARNING: Do not start the machine until all of the covers removed for maintenance have been refitted.
WARNING: Be absolutely certain to use the specified and standardized parts as replacement or consumable parts.
WARNING: Maintenance work should be carried out by qualified personnel in accordance with the instructions of the person in charge.
WARNING: Do not use compressed air to clean the machine or to remove chips.
WARNING: Use only the specified grades of hydraulic oil, lubricating oil, and grease or their equivalents.
WARNING: When changing a fuse, check that the new fuse has the correct rating.
Access the parts list for your equipment in MaintainX.
Line Filter, G-AK-12-50μk
G30TP002450
Scraper, SK-G-AK-12
G30TP00245A
Element, P-G-AK-12-50μk
G30TP00245B
Packing, T2 × φ17 (0.67)/φ8.5 (0.33)
G30TP00245C
O-Ring P-14, For Drain Plug
J2600P01400
Line Filter, G-AK-12-50μk
G30TP002450
Scraper, SK-G-AK-12
G30TP00245A
Element, P-G-AK-12-50μk
G30TP00245B
Packing, T2 × φ17 (0.67)/φ8.5 (0.33)
G30TP00245C
O-Ring P-14, For Drain Plug
J2600P01400
Line Filter, G-AK-12-50μk
G30TP002450
Scraper, SK-G-AK-12
G30TP00245A
Element, P-G-AK-12-50μk
G30TP00245B
Packing, T2 × φ17 (0.67)/φ8.5 (0.33)
G30TP00245C
O-Ring P-14, For Drain Plug
J2600P01400
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX













