MaintainX Asset Hub logo
EnterprisePricing
Mazak

Mazak Computer Numerical Control Machine QT-25L

Need answers fast?
Explore the manual using AI.

Mazak Computer Numerical Control Machine QT-25L
Mazak Computer Numerical Control Machine QT-25L

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Mazak Computer Numerical Control Machine QT-25L

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Mazak Computer Numerical Control Machine QT-25L

Mazak Computer Numerical Control Machine QT-25L

Create an account to install this asset package.

Maintenance Plans for Mazak Computer Numerical Control Machine Model QT-25L

Integrate maintenance plans directly into your work orders in MaintainX.

1 Daily Machine Inspection

Check mark

1. General: Arranging the machine periphery in order, cleaning the machine and its periphery (especially, the floor).

Check mark

2. Headstock:

Check mark

- Check the chuck unit and its periphery for chips.

Check mark

- Check for secure mounting of the top jaws.

Check mark

- Check for smooth chucking/unchucking.

Check mark

3. Tailstock:

Check mark

- Check the tailstock spindle for chips.

Check mark

- Check the tailstock body and tailstock spindle for smooth.

Check mark

4. Turret and X-axis:

Run this procedureArrow right

1 Yearly Machine Inspection

Check mark

1. Slideway and covers:

Check mark

- Check the wipers for abnormalities such as damage.

Check mark

2. Lubrication unit:

Check mark

- Clean the suction filters.

Check mark

- Clean the oiling filters

Check mark

- Check for oil leakage and for damaged piping.

Check mark

3. Foundation:

Check mark

- Check and adjust the bed level using a level.

Check mark

4. Grounding resistance:

Run this procedureArrow right

1 Monthly Machine Inspection

Check mark

1. Headstock:

Check mark

- Remove any chips from the coolant collector.

Check mark

2. Coolant unit:

Check mark

- Check the degree of dirtiness of the coolant and if necessary, replace.

Check mark

3. Electrical control cabinet:

Check mark

- Check the electrical components for dirt and discoloration and check for loose terminal screws.

Run this procedureArrow right

1 Yearly Filter Element Replacement

Check mark

Warning: This procedure requires trained personnel with PPE!

Check mark

Tool to be used: Allen wrench

Check mark

Remove the filter case

Check mark

Replace the hex socket head screw

Check mark

Pull out the baffle. The filter element can be removed

Check mark

Replace the filter element

Check mark

Fix the baffle

Check mark

Tighten the hex socket head screw

Check mark

Fix the filter case. Turn the filter case clockwise

Run this procedureArrow right

1 Yearly Suction Filter Cleaning

Check mark

Tools to be used: Wrench, Phillips screwdriver, Allen wrench

Check mark

1. Cleaning the suction filter. The suction filter in the lubricating oil reserve tank should be cleaned at least once a year.

Check mark

A. Open the side cover as illustrated below.

Check mark

B. Remove the pipes in the lubrication unit.

Check mark

C. Remove the clamp bolt.

Check mark

D. Pull out the lubrication unit.

Check mark

E. Remove the screws on the lubrication unit.

Check mark

F. Remove the pump from the tank. The suction filter can be seen.

Check mark

G. Remove the clamp.

Run this procedureArrow right

Parts for Mazak Computer Numerical Control Machine QT-25L

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

Pump PAVC16102L2

G09USA00020

Motor (Enclosed Fan Type) VM3561 TEFC 3-18-56C-440V-60

G70USA00020

Filter - Assembly 12AT10B015MML1

G30USA00020

Filter - Element 928763-10B

G30USA0002A

Oil Level Gauge LG-3

G29USA00010

Pump PAVC16102L2

G09USA00020

Motor (Enclosed Fan Type) VM3561 TEFC 3-18-56C-440V-60

G70USA00020

Filter - Assembly 12AT10B015MML1

G30USA00020

Filter - Element 928763-10B

G30USA0002A

Oil Level Gauge LG-3

G29USA00010

Pump PAVC16102L2

G09USA00020

Motor (Enclosed Fan Type) VM3561 TEFC 3-18-56C-440V-60

G70USA00020

Filter - Assembly 12AT10B015MML1

G30USA00020

Filter - Element 928763-10B

G30USA0002A

Oil Level Gauge LG-3

G29USA00010

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Mazak

Explore Other Assets