MaintainX Asset Hub logo
EnterprisePricing
KSB SE & Co. KGaA

KSB SE & Co. KGaA Standardised Water Pump ETN 200-150-250

Need answers fast?
Explore the manual using AI.

KSB SE & Co. KGaA Standardised Water Pump ETN 200-150-250
KSB SE & Co. KGaA Standardised Water Pump ETN 200-150-250

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for KSB SE & Co. KGaA Standardised Water Pump ETN 200-150-250

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

KSB SE & Co. KGaA Standardised Water Pump ETN 200-150-250

KSB SE & Co. KGaA Standardised Water Pump ETN 200-150-250

Create an account to install this asset package.

Maintenance Plans for KSB SE & Co. KGaA Standardised Water Pump Model ETN 200-150-250

Integrate maintenance plans directly into your work orders in MaintainX.

Filter Cleaning

Check mark

Monitor Filter Contamination

Check mark

Record the differential pressure gauge reading

Check mark

Is the differential pressure within the acceptable range?

Check mark

Filter Cleaning Process

Check mark

Turn off the pump before cleaning the filter

Check mark

Remove and clean the filter

Check mark

Reinstall the cleaned filter

Check mark

Post-Cleaning Check

Check mark

Is the filter properly installed and secured?

Run this procedureArrow right

Bearing Seal Inspection

Check mark

Seal Ring Inspection

Check mark

Check correct seating of axial seal rings mounted on the shaft

Check mark

Is there only gentle contact of the sealing lip?

Check mark

Safety Check

Check mark

Ensure no excessive temperatures caused by mechanical contact

Run this procedureArrow right

Coupling Inspection

Check mark

Coupling Check

Check mark

Inspect the flexible elements of the coupling for wear

Check mark

Is replacement of any coupling parts necessary?

Check mark

Check the alignment of the coupling

Check mark

Safety Inspection

Check mark

Inspect the coupling guard for deformation

Check mark

Check plastic components for deformation

Check mark

Ensure sufficient distance of guards from rotating parts

Run this procedureArrow right

Pump Set Assembly

Check mark

Safety Precautions

Check mark

Use suitable transport devices, lifting equipment and lifting tackle to move heavy assemblies or components.

Check mark

Reassembly Guidelines

Check mark

Reassemble the pump in accordance with the general rules of sound engineering practice.

Check mark

Use original spare parts only.

Check mark

Reassemble the pump according to the general assembly drawing or exploded view.

Check mark

Seal Elements Inspection

Check mark

Check O-rings for any damage and replace if required.

Check mark

Use new gaskets with the same thickness as the old ones.

Run this procedureArrow right

1 Weekly Pump Set Inspection

Check mark

Operational Observations

Check mark

Pump runs quietly and free from vibrations

Check mark

Is the oil level correct for oil lubrication?

Check mark

Shaft seal is in good condition

Check mark

Static seals are free from leakage

Check mark

Rolling element bearings are free from running noises

Check mark

Auxiliary connections are functioning correctly

Check mark

Stand-by Pump Monitoring

Check mark

Start the stand-by pump to ensure readiness for operation

Run this procedureArrow right

Parts for KSB SE & Co. KGaA Standardised Water Pump ETN 200-150-250

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

Shaft

210

Impeller

230

Deep Groove Ball Bearing

321.01/.02

Mechanical Seal, Complete Versions With Gland Packing

433

Casing Cover

161

Shaft

210

Impeller

230

Deep Groove Ball Bearing

321.01/.02

Mechanical Seal, Complete Versions With Gland Packing

433

Casing Cover

161

Shaft

210

Impeller

230

Deep Groove Ball Bearing

321.01/.02

Mechanical Seal, Complete Versions With Gland Packing

433

Casing Cover

161

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from KSB SE & Co. KGaA

Explore Other Assets