The Komatsu Hydraulic Excavator PC450LC-8 is a robust and efficient machine designed for heavy-duty excavation tasks. Known for its reliability and advanced hydraulic systems, this excavator excels in various construction and earthmoving applications, ensuring optimal performance and productivity on job sites.
Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Komatsu Hydraulic Excavator PC450LC-8
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
1000 Hourly Hydraulic Excavator Maintenance
REPLACE FUEL MAIN FILTER CARTRIDGE
WARNING
After the engine has been operated, all parts are at high temperature, so do not replace the filter immediately. Wait for all parts to cool down before starting the operation.
High pressure is generated inside the engine fuel piping system when the engine is running.
When replacing the filter, wait for at least 30 seconds after stopping the engine to let the internal pressure go down before replacing the filter.
Do not bring any fire or flame close.
Be careful when opening the air bleed plug in the fuel filter head. It is still under pressure, so fuel may spurt out.
NOTICE
Genuine Komatsu fuel filter cartridges use a special filter that has highly efficient filtering ability. When replacing the filter cartridge, always use a genuine Komatsu part.
2000 Hourly Hydraulic Excavator Maintenance
CHANGE OIL IN FINAL DRIVE CASE
WARNING
The parts and oil are at high temperature immediately after the engine is stopped, and may cause serious burns. Wait for the temperature to go down before starting the operation.
If there is still pressure remaining inside the case, the oil or plug may fly out.
Loosen the plug slowly to release the pressure.
Refill capacity: each 10.5 liters (2.77 US gal)
Prepare a handle.
1. Set the TOP mark at the top, with the TOP mark and plug (P) perpendicular to the ground surface.
2. Set a container under plug (P) to catch the oil.
250 Hourly Hydraulic Excavator Maintenance
LUBRICATE SWING CIRCLE
1. Lower the work equipment to the ground.
2. Using a grease pump, pump in grease through the grease fittings shown by arrows. (2 places)
3. After greasing, wipe off any old grease that was pushed out.
CHECK LEVEL OF BATTERY ELECTROLYTE
Carry out this procedure before operating the machine.
WARNING
Do not use the battery if the battery electrolyte level is below the LOWER LEVEL line. This will accelerate deterioration of the inside of the battery and reduce the service life of the battery. In addition, it may cause an explosion.
The battery generates flammable gas and there is danger of explosion, do not bring fire or sparks near the battery.
4000 Hourly Hydraulic Excavator Maintenance
Warning: This maintenance check requires trained personnel with PPE!
Check water pump for play in pulley, oil leaks, and water leaks
If any issues are found with the water pump, contact your Komatsu distributor for inspection, overhaul or replacement
Check starting motor
If the engine is started frequently, have this inspection carried out every 1000 hours
Replace accumulator (for control circuit) every 2 years or every 4000 hours, whichever comes sooner
Warning: The accumulator is charged with high-pressure nitrogen gas, so mistaken operation may cause an explosion, which will lead to serious injury or damage
When handling the accumulator, always do as follows:
Accumulator handling precautions
5000 Hourly Hydraulic Excavator Maintenance
WARNING: The parts and oil are at high temperature immediately after the engine is stopped, and may cause burns. Wait for the temperature to go down before starting the work.
When removing the oil filler cap, turn it slowly to release the internal pressure, then remove it.
NOTICE: If the machine is equipped with a hydraulic breaker, the hydraulic oil will deteriorate much faster than during normal bucket operations.
Refill capacity: 248 liters (65.52 US gal)
Prepare a handle (for the socket wrench).
Swing the upper structure so that hydraulic tank drain plug (P) and drain plug (A) at the bottom of the pump suction tube are in the middle between the left and right tracks.
Retract the arm and bucket cylinders, then lower the boom and put the teeth in contact with the ground.
Set the lock lever to the LOCK position and stop the engine.
Remove the cap of oil filler port (F) at the top of the hydraulic tank.
Access the parts list for your equipment in MaintainX.
Additional Breather For Hydraulic Tank Element
421-60-35170
Additional Filter For Breaker (If Equipped) Element
208-970-5121
Additional Filter For Breaker (If Equipped) (O-Ring)
07000-12011
Additional Filter For Breaker (If Equipped) (O-Ring)
07000-02125
Air Cleaner Element Assembly
600-185-6100
Additional Breather For Hydraulic Tank Element
421-60-35170
Additional Filter For Breaker (If Equipped) Element
208-970-5121
Additional Filter For Breaker (If Equipped) (O-Ring)
07000-12011
Additional Filter For Breaker (If Equipped) (O-Ring)
07000-02125
Air Cleaner Element Assembly
600-185-6100
Additional Breather For Hydraulic Tank Element
421-60-35170
Additional Filter For Breaker (If Equipped) Element
208-970-5121
Additional Filter For Breaker (If Equipped) (O-Ring)
07000-12011
Additional Filter For Breaker (If Equipped) (O-Ring)
07000-02125
Air Cleaner Element Assembly
600-185-6100
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX