Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Gast Manufacturing Air Motor 2AM-FCC-1
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
1 Daily Oil Level Check
OPERATION
Check the oil level daily
Use Gast #AD220 or a detergent SAE #10 automotive engine oil for lubricating
Air Motor Surface Temperature Inspection
Operation
Operate the motor for approximately 2 hours at the maximum desired load
Measure the surface temperature of the motor on the casting opposite the pipe ports
Is the surface temperature within the normal range (not exceeding 275 degrees F/135 degrees C)?
Consult with your Gast Distributor/Representative if the temperature exceeds the listed value
Air Motor Flushing
MAINTENANCE - Flushing
Ensure safety precautions are followed
Disconnect air line and muffler
Select the type of flushing solvent used
If using liquid solvent, pour several tablespoons directly into the intake port
If using Gast #AH255B, spray solvent into intake port
Rotate the shaft by hand in both directions for a few minutes
Wear eye protection, cover exhaust with a cloth and reconnect the air line
Restart the motor at a low pressure
3 Monthly Sound Absorber Cleaning
MAINTENANCE - Cleaning the sound absorber
Inspect muffler for non-lubricated operation
Change muffler element to avoid excessive clogging
Disconnect air supply and vent all air lines
Wear eye protection
Flush product in a well ventilated area
Avoid using kerosene or other combustible solvents
Remove the sound absorber
Clean the felt filter
Initial 500 Hours Filter Inspection
MAINTENANCE - Automatic Lubrication
Check intake and exhaust filters after first 500 hours of operation
Clean filters
Determine how frequently filters should be checked during future operation
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX