Gast Manufacturing Air Motor 1UP-NRV-10
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
Air Motor Surface Temperature Inspection
Operation
Operate the motor for approximately 2 hours at the maximum desired load
Measure the surface temperature of the motor on the casting opposite the pipe ports
Is the surface temperature within the normal range (not exceeding 275 degrees F/135 degrees C)?
Do not continue to operate the motor if the measured surface temperature exceeds the temperature listed on the motor
Consult with your Gast Distributor/Representative if the measured temperature exceeds the listed value
1 Daily Oil Level Check
Operation
Check the oil level daily
Select the oil type used for lubricating
Spur Gear Reducer Oil Level Check
SPUR AND WORM REDUCERS - Lubrication
Check the oil level in spur gear reducers stored or not operated for a period of time
Ensure gear motors have proper lubrication
Verify oil level is sufficient to prevent performance loss, damage, or failure
Use a 300 ssu at 100°F/38°C turbine quality lubricant
For horizontal operation, remove both plugs and add oil to top hole until other hole overflows
For vertical operation, fill to overflow point of upper most hole
3 Monthly Sound Absorber Cleaning
MAINTENANCE - Cleaning the sound absorber
Ensure safety precautions are followed
Remove the sound absorber
Clean the felt filter
For lubricated operation, did you add 3-4 drops of oil?
Check the air compressor
Listen for changes in the sound of the motor. Does the motor sound smooth?
If the motor does not sound smooth, is installing a service kit required?
Initial 500 Hours Filter Inspection
MAINTENANCE - Automatic Lubrication
Check intake and exhaust filters after first 500 hours of operation
Clean filters
Determine how frequently filters should be checked during future operation
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX