MaintainX Asset Hub logo
EnterprisePricing
Flowserve

Flowserve Pump MK3 HSI 8×6-16

Need answers fast?
Explore the manual using AI.

Flowserve Pump MK3 HSI 8×6-16
Flowserve Pump MK3 HSI 8×6-16

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Flowserve Pump MK3 HSI 8×6-16

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Flowserve Pump MK3 HSI 8×6-16

Flowserve Pump MK3 HSI 8×6-16

Create an account to install this asset package.

Maintenance Plans for Flowserve Pump Model MK3 HSI 8×6-16

Integrate maintenance plans directly into your work orders in MaintainX.

6 Weekly Bearing Re-Lubrication

Check mark

Regreasable Bearings - Lubrication Intervals

Check mark

Is the grease lubrication option specified?

Check mark

Measure the bearing housing operating temperature

Check mark

Is the operating temperature between 80-94°C (175-200°F)?

Check mark

Is the external housing temperature below 94°C (200°F)?

Check mark

Preparation for Relubrication

Check mark

Stop the pump and lock the motor

Check mark

Remove the coupling guard

Check mark

Relubrication Process

Run this procedureArrow right

18 Monthly Bearing Housing Oil Change

Check mark

Oil Bath Lubrication Intervals

Check mark

Is synthetic oil lubricant being used?

Check mark

Is the interval 18 months regardless of operating temperature?

Check mark

Can the interval be increased to 36 months with ANSI 3A power end?

Check mark

Temperature Checks

Check mark

Record the external housing temperature

Check mark

Is the external housing temperature below 82°C (180°F)?

Check mark

Is the bearing temperature below 105°C (220°F)?

Check mark

Oil Type and Compatibility

Run this procedureArrow right

Bearing Inspection

Check mark

6.1 Maintenance schedule

Check mark

Confirm satisfactory operation by checking

Check mark

Record the surface temperature at the bearings

Check mark

Is the surface temperature within the acceptable range?

Check mark

Ensure overload prevention measures are in place

Check mark

Perform routine vibration monitoring

Check mark

Check and remove dirt from areas around close clearances, bearing housings, and motors

Run this procedureArrow right

6 Monthly Bearing Re-Lubrication

Check mark

5.2.2.1 Regreasable — Figure 5-6: Lubrication intervals

Check mark

Is the grease lubrication option specified and bearing housing operating temperature under 71°C (160°F)?

Check mark

Enter the current external housing temperature in °C

Check mark

Is the external housing temperature below 94°C (200°F)?

Check mark

Is the bearing temperature below 105°C (220°F)?

Check mark

Select the grease type used for relubrication

Check mark

Have the bearings been relubricated three times since the last cleaning?

Check mark

Clean out the bearing housing if relubricated three times

Check mark

Ensure no oil is filled in the housing when greased bearings are used

Run this procedureArrow right

6 Weekly Bearing Housing Oil Change

Check mark

Oil Bath Lubrication Intervals

Check mark

Record the bearing housing operating temperature

Check mark

Is the operating temperature between 80-94°C (175-200°F)?

Check mark

Is the external housing temperature below 82°C (180°F)?

Check mark

Oil Specifications and Precautions

Check mark

Ensure oil meets the following specifications

Check mark

Is the oil a quality mineral oil with rust and oxidation inhibitors (e.g., Mobil DTE heavy/medium or equivalent)?

Check mark

Oil Change Procedure

Check mark

Clean the area around the vent plug [6521] at the top of the bearing housing

Run this procedureArrow right

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Flowserve

Explore Other Assets