DRAEGER Anesthesia Workstation Primus
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
Water Trap Container Removal
Water Trap Removal and Emptying
Pull the water trap out towards the front
Empty the water trap
Safety Warning
Ensure the water trap has not been used longer than four weeks
Disposal Instructions
Dispose of the old water trap according to WaterLock instructions
Comply with the hospital’s hygiene requirements during disposal
Ventilator Diaphragm Removal
Diaphragm Removal
Remove the upper diaphragm (A)
Is the diaphragm removed without damage?
Preparation for Conditioning
Prepare diaphragm for conditioning in a cleaning and disinfecting machine
Ensure diaphragm is not reprocessed with light-colored, transparent silicone components
Microbial Filter Removal
Filter Removal
Pull the filter off the nozzle
Filter Conditioning Preparation
Prepare the microbial filter for conditioning according to the corresponding instructions for use
Post Removal Check
Check that the filter has been removed completely
Inspect the nozzle for any remaining debris
Documentation
Record any issues encountered during removal
4 Weekly Water Trap Replacement
Procedure Description
Water Trap Replacement Steps
Pull the old water trap off to the front and dispose of it with domestic waste. Observe the hospital's hygiene regulations!
Mark the new water trap with the current date. Use the space provided for this purpose.
Push the new water trap into place until it engages.
Post Replacement Check
Is the monitor free of alarm messages after replacement?
Check if the new water trap is securely engaged.
Sample Line Removal
Sample Line Disconnection
Unscrew the sample line from the Y-piece
Unscrew the sample line from the water trap on the front of the unit
Safety Precautions
Ensure no gas measurement failure risk
Ensure device is not at risk of failure
Disposal Instructions
Dispose of the sample gas line according to hospital's hygiene regulations
Cautionary Notes
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.