MaintainX Logo
EnterprisePricing
Doosan

Doosan Generator G125

Need answers fast?
Explore the manual using AI.

Doosan Generator G125
Doosan Generator G125

The Doosan Generator G125 is a robust industrial generator designed for reliable power generation in various applications. Known for its efficiency and durability, this model provides essential backup power solutions, making it ideal for construction sites, events, and emergency services. Ensure optimal performance with regular maintenance and quality spare parts.

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Doosan Generator G125

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Doosan Generator G125

Doosan Generator G125

Create an account to install this asset package.

Maintenance Plans for Doosan Generator Model G125

Integrate maintenance plans directly into your work orders in MaintainX.

500 Hourly / 3 Monthly Air Cleaner Maintenance

Check mark

Proper maintenance of the air cleaner provides maximum protection against airborne dust.

Check mark

Squeeze the rubber valve (precleaner dirt dump periodically to ensure that it is not clogged).

Check mark

To service the air cleaners, proceed as follows:

Check mark

Remove filter element.

Check mark

Inspect air cleaner housing for any condition that might cause a leak and correct as necessary.

Check mark

Wipe inside of air cleaner housing with a clean, damp cloth to remove any dirt accumulation. This will permit better seal for gasket on filter element.

Check mark

Install element.

Check mark

The air cleaner assembly (housing) should be inspected every 3 months or 500 hours for any leakage paths.

Check mark

Make sure the inlet is free from obstruction.

Run this procedureArrow right

20000 Hourly / 3 Monthly Alternator Bearings Replacement

Check mark

Safety Measures

Check mark

Servicing or troubleshooting must be carried out strictly in accordance with instructions so as to avoid the risk of accidents and to maintain the machine in its original state.

Check mark

All such operations performed on the alternator should be undertaken by personnel with training of electrical and mechanical components.

Check mark

Before any intervention on the machine, ensure that it cannot be started by a manual or automatic system and that you have understood the operating principles of the system.

Check mark

The bearings are greased for life: approximate life of the grease (depending on use) = 20,000 hours or 3 years.

Check mark

Enter the current hours of operation

Check mark

Enter the temperature rise in the bearings

Check mark

Does the temperature rise in the bearings exceed 60°C above the ambient temperature?

Check mark

Should this value be exceeded, the machine must be stopped and checks carried out.

Run this procedureArrow right

1 Weekly Engine Check

Check mark

1. Tires

Check mark

• Weekly check the condition of the tires, and gauge the air pressure. Tires that have cuts or cracks or little tread should be repaired or replaced.

Check mark

2. Check Precleaner Dumps.

Check mark

3. Check Battery Connections.;

Run this procedureArrow right

Alternator Maintenance

Check mark

Safety Measures

Check mark

• Servicing or troubleshooting must be carried out strictly in accordance with instructions so as to avoid the risk of accidents and to maintain the machine in its original state.

Check mark

• All such operations performed on the alternator should be undertaken by personnel with training of electrical and mechanical components.

Check mark

• Before any intervention on the machine, ensure that it cannot be started by a manual or automatic system and that you have understood the operating principles of the system.

Check mark

1. Cooling circuit

Check mark

• It is advisable to check that circulation of air is not reduced by partial blocking of the suction and discharge louvres: mud, fibre, grease, etc.

Check mark

2. Electrical servicing

Check mark

• Cleaning product for the windings

Check mark

WARNING! Do not use: Trichlorethylene, perchlorethylene, trichloroethane and any alkaline products.

Run this procedureArrow right

1 Daily Engine Check

Check mark

1. Wiring Routing Clamps

Check mark

• Daily check for loose wire routing clamps. Clamps must be secure and properly mounted. Also check wiring for wear, deterioration and vibration abrasion.

Check mark

2. Electrical Terminals

Check mark

• Check daily for evidence of arcing around electrical terminals.

Check mark

3. Grounding Circuit

Check mark

• Daily check that the grounding circuit is in accordance with the National Electrical Code Article 250-122 and the local code requirements. As a minimum, the copper wire size should be American Wire Gauge 8 (AWG#8) from the grounding terminal, frame, generator and engine block.

Check mark

4. Wiring Insulation

Check mark

Daily check for loose, or frayed wiring insulation or sleeving.

Check mark

5. Fuel/Water Separator

Run this procedureArrow right

Parts for Doosan Generator G125

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

Protec Eng Fluid - 1 gal

36875938

Engine Fuel Element

22206197

500 Hour Maintenance Kit (& Engine fluids fluids)

44003754

Protec Eng Fluid - 5 gal

54480918

500 Hour Maintenance Kit (without fluids)

44004000

Protec Eng Fluid - 1 gal

36875938

Engine Fuel Element

22206197

500 Hour Maintenance Kit (& Engine fluids fluids)

44003754

Protec Eng Fluid - 5 gal

54480918

500 Hour Maintenance Kit (without fluids)

44004000

Protec Eng Fluid - 1 gal

36875938

Engine Fuel Element

22206197

500 Hour Maintenance Kit (& Engine fluids fluids)

44003754

Protec Eng Fluid - 5 gal

54480918

500 Hour Maintenance Kit (without fluids)

44004000

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Doosan

Explore Other Assets