MaintainX Asset Hub logo
EnterprisePricing
Daikin

Daikin Screw Chiller EWLH080J-SS

Need answers fast?
Explore the manual using AI.

Daikin Screw Chiller EWLH080J-SS
Daikin Screw Chiller EWLH080J-SS

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Daikin Screw Chiller EWLH080J-SS

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Daikin Screw Chiller EWLH080J-SS

Daikin Screw Chiller EWLH080J-SS

Create an account to install this asset package.

Maintenance Plans for Daikin Screw Chiller Model EWLH080J-SS

Integrate maintenance plans directly into your work orders in MaintainX.

Screw Chiller Piping Leak Test

Check mark

Warning: This procedure should only be performed by a qualified technician.

Check mark

Was the unit checked for leaks by the manufacturer?

Check mark

After connection of the piping, perform the following steps:

Check mark

Leak test performed?

Check mark

Enter the value of air evacuated in the refrigerant piping (in mbars)

Check mark

Do not purge the air with refrigerants. Use a vacuum pump to vacuum the installation.

Check mark

Technician's signature

Run this procedureArrow right

Refrigerant Level Adjustment

Check mark

Perform an integral pre-start inspection as explained in 'BEFORE STARTING'

Check mark

Read the operation manual delivered with the unit

Check mark

Use the 1/4” SAE Flare stop valve on the filter drier to pre-charge the unit with the complete calculated precharge

Check mark

Do not operate the compressor for pre-charging, this to avoid compressor damage!

Check mark

After completion of procedure step 2, perform an 'initial start' test

Check mark

Start the compressor and wait for the compressor to go through the star/delta. Carefully check during start-up.

Check mark

Compressor is not producing any abnormal noise or vibration

Check mark

High pressure rises and low pressure drops within 10 seconds after to evaluate if the compressor is not operating in reverse due to wrong wiring

Check mark

No safeties are activated

Run this procedureArrow right

Screw Chiller Check

Check mark

Check for external damage

Check mark

Open all shut-off valves

Check mark

Install mainfuses, earth leak detector and mainswitch

Check mark

Supply the main voltage and check if it is within the allowable ±10% limits of the nameplate rating

Check mark

Supply water to the evaporator and verify if waterflow is within the limits as given in the table under “Water charge, flow and quality”

Check mark

The pipng must be completely purged

Check mark

Connect the pump contact(s) in series with the contact of the flowswitch(es), so that the unit can only come in operation when the waterpumps are running and the water flow is sufficient

Check mark

Check the oil level in the compressors

Check mark

Install the filter kit(s) supplied with the unit in front of the evaporator(s) water inlet

Run this procedureArrow right

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Daikin

Explore Other Assets