MaintainX Asset Hub logo
EnterprisePricing
Cornell Pump Company

Cornell Pump Company Pump 8NHTR

Need answers fast?
Explore the manual using AI.

Cornell Pump Company Pump 8NHTR
Cornell Pump Company Pump 8NHTR

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Cornell Pump Company Pump 8NHTR

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Cornell Pump Company Pump 8NHTR

Cornell Pump Company Pump 8NHTR

Create an account to install this asset package.

Maintenance Plans for Cornell Pump Company Pump Model 8NHTR

Integrate maintenance plans directly into your work orders in MaintainX.

2 Monthly Oil Frame Lip Seal Lubrication

Check mark

3200-902 Lubrication Instructions — Oil Lubricated Frame Pumps

Check mark

Ensure all oil-filled frames have lip seals in their bearing covers

Check mark

Locate grease fittings in the bearing cover at either end of the frame

Check mark

Apply a small amount of multiple-purpose grease to each lip seal

Run this procedureArrow right

3 Monthly Frame Oil Change — F5K

Check mark

3200-902 Lubrication Instructions — Oil Lubricated Frame Pumps

Check mark

Verify frame size and oil capacity

Check mark

Enter the oil renewal interval in months

Check mark

Ensure the pump is not operating before checking and filling oil

Check mark

Measure the oil level and fill to the indicated level on the housing

Check mark

Is the oil free from dirt and moisture?

Check mark

Verify oil type based on temperature

Check mark

Measure the bearing frame temperature at the drain connection

Check mark

Is the frame denoted by a 'K' on the serial number plate and a view gauge on the side?

Run this procedureArrow right

Wear Ring Inspection

Check mark

3200-326 Startup Checklist — Instructions for Pumps with Balance Line and Wear Rings

Check mark

Check wear ring clearance

Check mark

Is the wear ring clearance within acceptable limits?

Check mark

Inspect balance lines for obstructions

Check mark

Check balance lines for pinching, bending, or corrosion

Check mark

Replace wear rings if clearance exceeds .03" per side

Check mark

Replace balance lines if pinched, bent, or corroded

Run this procedureArrow right

5 Monthly Frame Oil Change — F16K

Check mark

Preparation

Check mark

Ensure the pump is not operating before starting the oil change.

Check mark

Verify the frame size and oil capacity

Check mark

Oil Change Procedure

Check mark

Remove the pipe plug at the top of the housing.

Check mark

Drain the old oil completely.

Check mark

Check for dirt and moisture in the housing and clean if necessary.

Check mark

Select the appropriate oil type based on temperature

Check mark

Add new oil through the pipe plug opening until it reaches the indicated level on the side of the housing.

Run this procedureArrow right

1 Daily Mechanical Seal Leakage Inspection

Check mark

3200-632 Maintenance — Instructions for Mechanical Seal

Check mark

Examine the pump for leakage

Check mark

Is the leakage reducing to almost zero?

Check mark

Examine the assembly for proper seal installation if leakage persists

Check mark

Ensure the pump is not run dry unless equipped with Run-Dry option

Run this procedureArrow right

Parts for Cornell Pump Company Pump 8NHTR

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

Cornell 60/40 Propylene Glycol Run-Dry Fluid With Corrosion Inhibitor

N10263-415

Cornell 60/40 Propylene Glycol Run-Dry Fluid With Corrosion Inhibitor

N10263-415

Cornell 60/40 Propylene Glycol Run-Dry Fluid With Corrosion Inhibitor

N10263-415

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Cornell Pump Company

Explore Other Assets