MaintainX Asset Hub logo
EnterprisePricing
Conair

Conair Thermolator Temperature Control Unit IC-12kW-460V

Need answers fast?
Explore the manual using AI.

Conair Thermolator Temperature Control Unit IC-12kW-460V
Conair Thermolator Temperature Control Unit IC-12kW-460V

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Conair Thermolator Temperature Control Unit IC-12kW-460V

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Conair Thermolator Temperature Control Unit IC-12kW-460V

Conair Thermolator Temperature Control Unit IC-12kW-460V

Create an account to install this asset package.

Maintenance Plans for Conair Thermolator Temperature Control Unit Model IC-12kW-460V

Integrate maintenance plans directly into your work orders in MaintainX.

1 Daily Unit Cleaning

Check mark

Unit and Surrounding Area Cleaning

Check mark

Clean the unit and the area around it

Check mark

Check for and remove obstructions

Check mark

Ensure air intake areas are clear

Check mark

Floor Maintenance

Check mark

Keep the floor around the unit dry

Run this procedureArrow right

1 Monthly Fluid Reservoir Inspection

Check mark

Initial Inspection

Check mark

Check the level switches in the process fluid reservoir for debris or deposits

Check mark

Is flushing and cleaning the reservoir necessary?

Check mark

Reservoir Filling Procedure

Check mark

Disconnect and lockout power

Check mark

Remove the top panel of the Thermolator

Check mark

Locate the reservoir near the top of the unit

Check mark

Locate the fill port at the top of the reservoir

Check mark

Monitor the fluid level using the sight glass on the back of the unit

Run this procedureArrow right

Solenoid Valves Maintenance

Check mark

Preparation

Check mark

Shut off the cooling water infeed

Check mark

Drain the unit of all water through the drain plugs in the rear of the unit

Check mark

Remove the cooling water out feed

Check mark

For closed and isolated circuit models, also remove the cooling water in feed

Check mark

Disconnect and lock out main power

Check mark

Disassembly

Check mark

Remove the top and side panels of the Thermolator

Check mark

Lift the top panel straight up, then lift the side panels up

Run this procedureArrow right

1 Yearly Unit Testing

Check mark

Preparation for Test Mode

Check mark

Shut down the Thermolator

Check mark

Disconnect and lock out main power to the unit

Check mark

Open the electrical enclosure

Check mark

Set dip switches

Check mark

Close the electrical enclosure

Check mark

Restore power to the unit

Check mark

Press any button to display the first test menu

Check mark

Key/Display Test

Run this procedureArrow right

Thermocouple Replacement

Check mark

Preparation

Check mark

Disconnect and lockout the main power

Check mark

Shut off the cooling water infeed and drain the unit

Check mark

Draining Water

Check mark

Drain all water using the drain plugs located at the bottom of the unit

Check mark

Accessing the Thermocouple

Check mark

Remove the unit’s top panel

Check mark

Open the electrical enclosure

Check mark

Removing the Old Thermocouple

Run this procedureArrow right

Parts for Conair Thermolator Temperature Control Unit IC-12kW-460V

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

¾ HP Pump Model 11C (With Cast Iron Impeller)

9000952

1 HP Pump Model 11C (With Cast Iron Impeller)

9000953

2 HP Pump Model 12C (With Brass Impeller)

9000954

3 HP Pump Model 50C (With Cast Iron Impeller)

9000955

5 HP Pump Model 50C (With Cast Iron Impeller)

9000956

¾ HP Pump Model 11C (With Cast Iron Impeller)

9000952

1 HP Pump Model 11C (With Cast Iron Impeller)

9000953

2 HP Pump Model 12C (With Brass Impeller)

9000954

3 HP Pump Model 50C (With Cast Iron Impeller)

9000955

5 HP Pump Model 50C (With Cast Iron Impeller)

9000956

¾ HP Pump Model 11C (With Cast Iron Impeller)

9000952

1 HP Pump Model 11C (With Cast Iron Impeller)

9000953

2 HP Pump Model 12C (With Brass Impeller)

9000954

3 HP Pump Model 50C (With Cast Iron Impeller)

9000955

5 HP Pump Model 50C (With Cast Iron Impeller)

9000956

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Conair

Explore Other Assets