MaintainX Asset Hub logo
EnterprisePricing
Burton Medical

Burton Medical Medical Light A51W

Need answers fast?
Explore the manual using AI.

Burton Medical Medical Light A51W
Burton Medical Medical Light A51W

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Burton Medical Medical Light A51W

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Burton Medical Medical Light A51W

Burton Medical Medical Light A51W

Create an account to install this asset package.

Maintenance Plans for Burton Medical Medical Light Model A51W

Integrate maintenance plans directly into your work orders in MaintainX.

Bulb Replacement

Check mark

Safety Precautions

Check mark

Ensure the fixture is cool before starting the replacement process.

Check mark

Verify that the power is turned off before replacing the bulb.

Check mark

Bulb Replacement Process

Check mark

Use a small Phillips screwdriver to loosen the retaining screw at the pod.

Check mark

Remove the pod.

Check mark

Slide the bulb/socket assembly back and away from the wire retainer.

Check mark

Gently wiggle the bulb to separate it from the socket.

Check mark

Use gloves or a dry tissue when replacing the bulb. Pull it straight out of the socket.

Run this procedureArrow right

Fuse Replacement

Check mark

Floor Stand Version

Check mark

Unplug the power cord before replacing fuses

Check mark

Use a flat screwdriver to open the fuse holder and replace the fuse(s)

Check mark

Ceiling Versions 120V

Check mark

Disconnect power to the lamp circuit at the main breaker before replacing the fuse

Check mark

Use a flat screwdriver to open the fuse holder and replace the fuse

Check mark

Ceiling Versions 100V, 230V, 240V

Check mark

Remove the ceiling dome by loosening the two set screws on the locking ring

Check mark

Replace the fuse

Run this procedureArrow right

1300 Hourly / 12 Monthly Light Maintenance

Check mark

WARNING: Maintenance Schedule Suggestion

Check mark

WARNING: Equipment Malfunction

Check mark

Light Maintenance Steps

Check mark

Remove top housing

Check mark

Clean accessible parts

Check mark

Check friction between light head and yoke shaft

Check mark

Adjust friction between light head and yoke shaft if needed

Run this procedureArrow right

Light Head Rotating Friction Adjustment

Check mark

Preparation

Check mark

Remove the pods to access the screws holding the housing together

Check mark

Remove the screws

Check mark

Adjustment

Check mark

Lift the top housing off

Check mark

Use a wrench to tighten the nuts on each shaft

Check mark

Rotate the light head to verify correct friction

Check mark

Reassembly

Check mark

Re-assemble the housing

Run this procedureArrow right

Light Normal Cleaning

Check mark

WARNING: Electrical shock

Check mark

Power off the equipment and secure it from being switched on again.

Check mark

NOTE: Damage to equipment

Check mark

Ensure only approved cleaning agents are used

Check mark

Cleaning Procedure

Check mark

Use a soft cloth dampened with a mild detergent solution for basic cleaning of all surfaces.

Check mark

For stubborn stains, use a soft cloth soaked in isopropyl alcohol.

Run this procedureArrow right

Parts for Burton Medical Medical Light A51W

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

Bulb (A50); Halogen, 50W MR16 12V

6000120PK

AIM 50 / AIM 100 / AIM 200; 230V, 240V Version: Fuse T, 1A, 250V, 5x20mm

1017229

Window (A50)

5000119

Reflector

1019000

Disposable Cover

0008100PK

Bulb (A50); Halogen, 50W MR16 12V

6000120PK

AIM 50 / AIM 100 / AIM 200; 230V, 240V Version: Fuse T, 1A, 250V, 5x20mm

1017229

Window (A50)

5000119

Reflector

1019000

Disposable Cover

0008100PK

Bulb (A50); Halogen, 50W MR16 12V

6000120PK

AIM 50 / AIM 100 / AIM 200; 230V, 240V Version: Fuse T, 1A, 250V, 5x20mm

1017229

Window (A50)

5000119

Reflector

1019000

Disposable Cover

0008100PK

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Burton Medical

Explore Other Assets