MaintainX Asset Hub logo
EnterprisePricing
Burton Medical

Burton Medical Medical Light A53W

Need answers fast?
Explore the manual using AI.

Burton Medical Medical Light A53W
Burton Medical Medical Light A53W

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Burton Medical Medical Light A53W

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Burton Medical Medical Light A53W

Burton Medical Medical Light A53W

Create an account to install this asset package.

Maintenance Plans for Burton Medical Medical Light Model A53W

Integrate maintenance plans directly into your work orders in MaintainX.

Light Extensive Cleaning

Check mark

Preparation

Check mark

Ensure the light is turned off and unplugged

Check mark

Removing Top Housing

Check mark

Remove pods to access screws (if applicable)

Check mark

Remove screws to detach top housing

Check mark

Cleaning Process

Check mark

Use a soft cloth to wipe corners and surfaces

Check mark

Ensure no components inside the light head are bent

Check mark

Reassembly

Run this procedureArrow right

Fuse Replacement

Check mark

Floor Stand Version

Check mark

Unplug the power cord before replacing fuses

Check mark

Use a flat screwdriver to open the fuse holder and replace the fuse(s)

Check mark

Ceiling Versions 120V

Check mark

Disconnect power to the lamp circuit at the main breaker before replacing the fuse

Check mark

Use a flat screwdriver to open the fuse holder and replace the fuse

Check mark

Ceiling Versions 100V, 230V, and 240V

Check mark

Remove the ceiling dome by loosening the two set screws on the locking ring

Check mark

Replace the fuse and re-assemble in the opposite order

Run this procedureArrow right

Arm Tension Adjustment

Check mark

Remove Plastic Cap

Check mark

Remove the plastic cap covering the rotating mechanism by pulling it away from the assembly.

Check mark

Adjust Tension Screw

Check mark

Use a common screwdriver to adjust the screw.

Check mark

Direction to adjust the screw

Check mark

Does the lighthead remain balanced when moved slightly up or down at mid-range?

Check mark

Replace Plastic Cap

Check mark

Snap the plastic cap back into position.

Run this procedureArrow right

1300 Hourly / 12 Monthly Light Maintenance

Check mark

WARNING: Maintenance Schedule Suggestion

Check mark

WARNING: Equipment Malfunction

Check mark

Remove top housing and clean accessible parts

Check mark

Check and adjust friction between light head and yoke shaft if needed

Check mark

Post Maintenance Check

Check mark

Ensure all tools are removed from the work area

Check mark

Verify that the light functions correctly after maintenance

Run this procedureArrow right

1 Weekly Light Check

Check mark

WARNING: Maintenance Schedule Suggestion

Check mark

WARNING: Equipment Functionality

Check mark

Light Movement and Security Check

Check mark

Check that the light is easy to move in its range of movement, and that it holds its position without drifting

Check mark

Check that all components appear secure

Check mark

Post-Check Actions

Check mark

Is the light functioning properly after the checks?

Check mark

Describe any issues found during the check

Check mark

Technician's signature

Run this procedureArrow right

Parts for Burton Medical Medical Light A53W

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

Bulb (A50); Halogen, 50W MR16 12V

6000120PK

AIM 50 / AIM 100 / AIM 200; 230V, 240V Version: Fuse T, 1A, 250V, 5x20mm

1017229

Window (A50)

5000119

Reflector

1019000

Disposable Cover

0008100PK

Bulb (A50); Halogen, 50W MR16 12V

6000120PK

AIM 50 / AIM 100 / AIM 200; 230V, 240V Version: Fuse T, 1A, 250V, 5x20mm

1017229

Window (A50)

5000119

Reflector

1019000

Disposable Cover

0008100PK

Bulb (A50); Halogen, 50W MR16 12V

6000120PK

AIM 50 / AIM 100 / AIM 200; 230V, 240V Version: Fuse T, 1A, 250V, 5x20mm

1017229

Window (A50)

5000119

Reflector

1019000

Disposable Cover

0008100PK

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Burton Medical

Explore Other Assets