MaintainX Logo
EnterprisePricing
Branson Ultrasonics

Branson Ultrasonics Ultrasonic Vapor Degreaser B1950

Need answers fast?
Explore the manual using AI.

Branson Ultrasonics Ultrasonic Vapor Degreaser B1950
Branson Ultrasonics Ultrasonic Vapor Degreaser B1950

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Branson Ultrasonics Ultrasonic Vapor Degreaser B1950

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Branson Ultrasonics Ultrasonic Vapor Degreaser B1950

Branson Ultrasonics Ultrasonic Vapor Degreaser B1950

Create an account to install this asset package.

Maintenance Plans for Branson Ultrasonics Ultrasonic Vapor Degreaser Model B1950

Integrate maintenance plans directly into your work orders in MaintainX.

Controller Replacement

Check mark

Warning: Disconnect the degreaser from electrical power before starting the procedure.

Check mark

Degreaser disconnected from electrical power?

Check mark

To replace the control or relay board

Check mark

All wires transferred to the new board?

Check mark

Mounting screws removed?

Check mark

New board replaced?

Check mark

Screws reinstalled?

Check mark

To replace the control board

Check mark

Voltage Switch (SW1) placed in the 230V position?

Run this procedureArrow right

Degreaser Inspection

Check mark

Warning: Ensure to wear appropriate safety gear during the inspection

Check mark

Check for loosening of plumbing connections

Check mark

Check for leaks in solvent systems

Check mark

Upload a photo of the area where the leak is detected

Check mark

Describe the location and severity of the leak

Check mark

Check for dampness or cold spots caused by evaporative cooling

Check mark

Select the method used for leak detection

Check mark

Upload a photo of the leak detection method used

Check mark

Describe the results of the leak detection method used

Run this procedureArrow right

Filter Maintenance

Check mark

Filter bags are industry standard RBX-1 size (Trade size 3). Bags are available from the Branson Parts Department : 1 877-330-0406 ext 2065. Replacement 5mic Bag Filter CPN-163-018, other sizes are also available.

Check mark

Clean filter bags when the recirculation flow is reduced or when the bag becomes 1/3 full of soil.

Check mark

Replace filter bags if the fabric is damaged or if the pores become clogged with waxes.

Check mark

To clean the filter:

Check mark

• Turn off “Recirculation”

Check mark

• Close both the supply and return recirculation ball valves.

Check mark

• Unfasten and remove the canister cover clamp.

Check mark

• Remove the cover. Inspect o-ring gasket, replace if damage or kinked

Check mark

• Replacement O-ring Teflon Enc Silicone CPN-142-210

Run this procedureArrow right

Degreaser Cleaning

Check mark

Boil Down

Check mark

Is the CONTAMINATION WARNING Indicator lighted but the degreaser has not shut down on B/S TEMP FAULT?

Check mark

Remove 2-3 inches of solvent from the ultrasonic sump.

Check mark

Did you turn on the heat?

Check mark

Did you monitor the level in the ultrasonic sump?

Check mark

Did you allow the degreaser to boil until it shuts down on B/S TEMP FAULT or B/S LEVEL FAULT?

Check mark

Did you drain the solvent from the boil sump?

Check mark

Did you refill the degreaser using the solvent removed in the first step?

Check mark

Cleanout Procedure

Run this procedureArrow right

Dessicant Replacement

Check mark

Desiccant is used with solvents containing alcohol or other additives that are soluble in water.

Check mark

Consult the solvent manufacturer to determine if your solvent requires desiccant.

Check mark

Desiccant must be tested routinely and changed when necessary. It may be regenerated and reused; check with the desiccant manufacturer for regeneration instructions.

Check mark

5.5.1 Testing Frequency

Check mark

The rate of desiccant exhaustion is determined by the amount of water introduced by the parts, the ambient humidity and the temperature of the condensing and cold trap coils.

Check mark

Note: For maximum solvent and equipment life, do not allow the desiccant to become fully loaded with water. Change the desiccant before the desiccant test shows positive. Use the following guidelines to determine testing frequency for your local conditions. The guidelines also detail how to obtain the maximum life from the desiccant.

Check mark

• Each working shift, test the solvent leaving the water separator until you can establish a baseline. For example: After testing the desiccant twice per shift and changing the desiccant three times, you may determine that the SHORTEST desiccant life is four days and the LONGEST desiccant life is six days.

Check mark

• Revise your testing schedule. Continuing the example above: Test on the third day and then daily until the desiccant needs to be changed.

Check mark

• If you observe free water in the desiccant chamber, then change the desiccant regardless of the test results.

Run this procedureArrow right

Parts for Branson Ultrasonics Ultrasonic Vapor Degreaser B1950

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

Electronic Leak Detector

CPN-068-005

Filter Bag

CPN-163-018

O-ring Teflon Enc Silicone

CPN-142-210

Dessicator Test Kit

000-870-901

O-ring Teflon Cleanout

CPN-087-015

Electronic Leak Detector

CPN-068-005

Filter Bag

CPN-163-018

O-ring Teflon Enc Silicone

CPN-142-210

Dessicator Test Kit

000-870-901

O-ring Teflon Cleanout

CPN-087-015

Electronic Leak Detector

CPN-068-005

Filter Bag

CPN-163-018

O-ring Teflon Enc Silicone

CPN-142-210

Dessicator Test Kit

000-870-901

O-ring Teflon Cleanout

CPN-087-015

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Branson Ultrasonics

Explore Other Assets