MaintainX Logo
EnterprisePricing
Branson Ultrasonics

Branson Ultrasonics Ultrasonic Vapor Degreaser B950

Need answers fast?
Explore the manual using AI.

Branson Ultrasonics Ultrasonic Vapor Degreaser B950
Branson Ultrasonics Ultrasonic Vapor Degreaser B950

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Branson Ultrasonics Ultrasonic Vapor Degreaser B950

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Branson Ultrasonics Ultrasonic Vapor Degreaser B950

Branson Ultrasonics Ultrasonic Vapor Degreaser B950

Create an account to install this asset package.

Maintenance Plans for Branson Ultrasonics Ultrasonic Vapor Degreaser Model B950

Integrate maintenance plans directly into your work orders in MaintainX.

Degreaser Inspection

Check mark

Warning: Ensure to wear appropriate safety gear during inspection

Check mark

Check for loosening of plumbing connections

Check mark

Check for leaks in solvent systems

Check mark

Note any dampness or cold spots

Check mark

Dye added to the solvent for leak detection?

Check mark

Note: Dyes may be difficult to remove when the degreaser is later used for cleaning.

Check mark

Upload a photo of the degreaser

Check mark

Use electronic leak detector for solvent vapors

Check mark

Note any beeping noise indicating high concentrations of solvent vapors

Run this procedureArrow right

1 Daily Separator Cleaning

Check mark

Draining Water From Water Separator

Check mark

To use the separator/desiccator as a separator, do not install the desiccator bag.

Check mark

At least once each day, open the water separator water drain and collect the discharge into a container. When the flow stops, close the drain. The discharge will contain some dissolved or suspended solvent. Dispose of this residue in accordance with local regulations.

Run this procedureArrow right

6 Monthly Pump Lubrication

Check mark

Warning: Ensure the pump motors are turned off before starting the lubrication process.

Check mark

Are the pump motors turned off?

Check mark

Upload a photo of the pump motors before lubrication

Check mark

Enter the amount of machine oil used for lubrication

Check mark

Did the lift lower from an intermediate held position?

Check mark

Did you add lubricant?

Check mark

Upload a photo of the vertical air cylinder after lubrication

Check mark

Lubricating the cylinder directly

Check mark

Is the lift in the fully up position?

Run this procedureArrow right

Filter Maintenance

Check mark

Warning: Ensure to follow all safety guidelines while performing filter maintenance.

Check mark

Recirculation turned off

Check mark

Supply and return recirculation ball valves closed

Check mark

Canister cover clamp unfastened and removed

Check mark

Cover removed and o-ring gasket inspected

Check mark

Condition of the o-ring gasket

Check mark

Bag removed from the housing and solvent drained

Check mark

Bag suspended in the freeboard area until dripping stops

Check mark

Soils disposed of in accordance with local regulations

Run this procedureArrow right

Degreaser Cleaning

Check mark

Boil Down

Check mark

Is the CONTAMINATION WARNING Indicator lighted but the degreaser has not shut down on B/S TEMP FAULT?

Check mark

Remove 2-3 inches of solvent from the ultrasonic sump.

Check mark

Caution: Do not drain the ultrasonic sump below the top of the ultrasonic sump heater.

Check mark

Turn on the heat.

Check mark

Monitor the level in the ultrasonic sump. Drain additional solvent if it starts to overflow into the boil sump.

Check mark

Allow the degreaser to boil until it shuts down on B/S TEMP FAULT or B/S LEVEL FAULT.

Check mark

Drain the solvent from the boil sump.

Check mark

Refill the degreaser using the solvent removed in the first step. Add solvent as required.

Run this procedureArrow right

Parts for Branson Ultrasonics Ultrasonic Vapor Degreaser B950

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

Electronic Leak Detector

CPN-068-005

Filter Bag

CPN-163-018

O-ring Teflon Enc Silicone

CPN-142-210

Dessicator Test Kit

000-870-901

Desiccant Test Kit

000-870-901

Electronic Leak Detector

CPN-068-005

Filter Bag

CPN-163-018

O-ring Teflon Enc Silicone

CPN-142-210

Dessicator Test Kit

000-870-901

Desiccant Test Kit

000-870-901

Electronic Leak Detector

CPN-068-005

Filter Bag

CPN-163-018

O-ring Teflon Enc Silicone

CPN-142-210

Dessicator Test Kit

000-870-901

Desiccant Test Kit

000-870-901

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Branson Ultrasonics

Explore Other Assets