

Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

ABB Water Drive ACQ580-01-430A-4
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
9 Yearly R8 - R9 Second Auxiliary Cooling Fan Replacement
Fans
Parameter 05.04 Fan on-time counter indicates the running time of the cooling fan. Reset the counter after a fan replacement. See the firmware manual.
In a speed-controlled fan, the speed of the fan matches the cooling needs. This increases the life span of the fan.
Main fans are speed controlled. When the drive is stopped, the main fan runs at low speed until the drive cools down. IP21 (UL Type 1) frames R5..R9 and all IP55 (UL Type 12) frames have auxiliary fans that are not speed controlled and run all the time when the control unit is powered.
Replacement fans are available from the manufacturer. Do not use other than specified spare parts.
Electrical safety in installation, start-up and maintenance
Electrical safety precautions
These electrical safety precautions are for all personnel who do work on the drive, motor cable or motor.
WARNING!
1 Yearly Drive Inspection
Check quality of supply voltage
Inspect spare parts
Inspect tightness of terminals
Inspect dustiness, corrosion or temperature
Inspect IP66 (UL Type 4X) frames R1..R3: Drive cover and gasket assembly
9 Yearly R3, R4 - R5, R6 - R9 Auxiliary Cooling Fan Replacement
Fans
Parameter 05.04 Fan on-time counter indicates the running time of the cooling fan. Reset the counter after a fan replacement. See the firmware manual.
In a speed-controlled fan, the speed of the fan matches the cooling needs. This increases the life span of the fan.
Main fans are speed controlled. When the drive is stopped, the main fan runs at low speed until the drive cools down. IP21 (UL Type 1) frames R5..R9 and all IP55 (UL Type 12) frames have auxiliary fans that are not speed controlled and run all the time when the control unit is powered.
Replacement fans are available from the manufacturer. Do not use other than specified spare parts.
Electrical safety in installation, start-up and maintenance
Electrical safety precautions
These electrical safety precautions are for all personnel who do work on the drive, motor cable or motor.
WARNING!
9 Yearly R6 - R8, R9 Main Cooling Fan Replacement
Fans
Parameter 05.04 Fan on-time counter indicates the running time of the cooling fan. Reset the counter after a fan replacement. See the firmware manual.
In a speed-controlled fan, the speed of the fan matches the cooling needs. This increases the life span of the fan.
Main fans are speed controlled. When the drive is stopped, the main fan runs at low speed until the drive cools down. IP21 (UL Type 1) frames R5..R9 and all IP55 (UL Type 12) frames have auxiliary fans that are not speed controlled and run all the time when the control unit is powered.
Replacement fans are available from the manufacturer. Do not use other than specified spare parts.
Electrical safety in installation, start-up and maintenance
Electrical safety precautions
These electrical safety precautions are for all personnel who do work on the drive, motor cable or motor.
WARNING!
9 Yearly R5, R6 - R9 Auxiliary Cooling Fan Replacement
Warning: This procedure requires a qualified electrical professional. Do not proceed if you are not qualified.
Before starting, identify the work location and equipment.
All possible voltage sources disconnected and re-connection locked out and tagged out?
All dangerous external voltages from the control circuits disconnected?
Waited 5 minutes after disconnecting power from the drive to let the intermediate circuit capacitors discharge?
Protected any other energized parts in the work location against contact?
Special precautions taken when close to bare conductors?
Voltage between the drive input power terminals (L1, L2, L3) and the grounding (PE) busbar
Voltage between the drive output terminals (T1/U, T2/V, T3/W) and the grounding (PE) busbar
Access the parts list for your equipment in MaintainX.
Phoenix Contact Subcon-Plus-Profib/PG/SC2
2708245
Profibus Bus Connector
6GK1 500 0EA02
Fuse, ABB Type
OFAF3H630
Fuse, Bussmann Type, DIN 43620 Blade Style
170M8554D
Fuse, Bussmann Type, DIN 43653 Bolted Tags
170M5013
Phoenix Contact Subcon-Plus-Profib/PG/SC2
2708245
Profibus Bus Connector
6GK1 500 0EA02
Fuse, ABB Type
OFAF3H630
Fuse, Bussmann Type, DIN 43620 Blade Style
170M8554D
Fuse, Bussmann Type, DIN 43653 Bolted Tags
170M5013
Phoenix Contact Subcon-Plus-Profib/PG/SC2
2708245
Profibus Bus Connector
6GK1 500 0EA02
Fuse, ABB Type
OFAF3H630
Fuse, Bussmann Type, DIN 43620 Blade Style
170M8554D
Fuse, Bussmann Type, DIN 43653 Bolted Tags
170M5013
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX













