MaintainX Asset Hub logo
EnterprisePricing
Mitsubishi

Mitsubishi Split-Type Air Conditioner MUZ-GC50NA

Need answers fast?
Explore the manual using AI.

Mitsubishi Split-Type Air Conditioner MUZ-GC50NA
Mitsubishi Split-Type Air Conditioner MUZ-GC50NA

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Mitsubishi Split-Type Air Conditioner MUZ-GC50NA

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Mitsubishi Split-Type Air Conditioner MUZ-GC50NA

Mitsubishi Split-Type Air Conditioner MUZ-GC50NA

Create an account to install this asset package.

Maintenance Plans for Mitsubishi Split-Type Air Conditioner Model MUZ-GC50NA

Integrate maintenance plans directly into your work orders in MaintainX.

Cabinet Disassemble

Check mark

Remove the screws of the service panel

Check mark

Remove the screws of the top panel

Check mark

Remove the screw of the valve cover

Check mark

Remove the service panel

Check mark

Remove the top panel

Check mark

Remove the valve cover

Check mark

Disconnect the power supply and indoor/outdoor connecting wire

Check mark

Remove the screws of the cabinet

Check mark

Remove the cabinet

Run this procedureArrow right

R.V. Coil Disassemble

Check mark

Remove the top panel, cabinet and service panel

Check mark

Remove the back panel

Check mark

Disconnect the following connectors; <Noise filter P.C. board> CN912 (R.V. coil)

Check mark

Remove the R.V. coil

Check mark

Upload a photo of the disassembled R.V. coil

Check mark

Sign off on the R.V. coil disassembly

Run this procedureArrow right

Thermistors Disassemble

Check mark

Remove the top panel, cabinet and service panel

Check mark

Remove the back panel

Check mark

Disconnect CN661 (Discharge temperature thermistor, defrost thermistor and outdoor heat exchanger temperature thermistor) from the Electronic control P.C. board

Check mark

Disconnect CN663 (Ambient temperature thermistor) from the Electronic control P.C. board

Check mark

Pull out the defrost thermistor from its holder

Check mark

Upload a photo of the defrost thermistor removed from its holder

Check mark

Pull out the discharge temperature thermistor from its holder

Check mark

Upload a photo of the discharge temperature thermistor removed from its holder

Check mark

Pull out the outdoor heat exchanger temperature thermistor from its holder

Run this procedureArrow right

Inverter Assembly, Inverter P.C. Board and Power Board Disassemble

Check mark

(1) Remove the top panel, cabinet and service panel. (Refer to 1.)

Check mark

(2) Remove the back panel. (Refer to 1.)

Check mark

(3) Disconnect the following connectors;

Check mark

<Electronic control P.C. board>

Check mark

CN931 and CN932 (Fan motor)

Check mark

CN795 (LEV)

Check mark

CN661 (Discharge temperature thermistor, defrost thermistor and outdoor heat exchanger temperature thermistor)

Check mark

CN663 (Ambient temperature thermistor)

Check mark

<Noise filter P.C. board>

Run this procedureArrow right

Reactor Disassemble

Check mark

Remove the top panel, cabinet, service panel and the back panel

Check mark

Upload a photo of the removed panels

Check mark

Disconnect the reactor lead wire

Check mark

Upload a photo of the disconnected lead wire

Check mark

Remove the screws of the reactor

Check mark

Upload a photo of the reactor without screws

Check mark

Remove the reactor

Check mark

Upload a photo of the removed reactor

Run this procedureArrow right

Parts for Mitsubishi Split-Type Air Conditioner MUZ-GC50NA

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

Fan Motor

RC0J60-AA

Compressor

SNB130FLDH1

Fan Motor

RC0J60-AA

Compressor

SNB130FLDH1

Fan Motor

RC0J60-AA

Compressor

SNB130FLDH1

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Mitsubishi

Explore Other Assets