Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

ABB Water Drive ACQ580-01-293A-4
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
6 Yearly R4 V2 IP21 Auxiliary Cooling Fan Replacement
Warning: This procedure requires a qualified electrical professional. Do not attempt if you are not qualified.
Before starting, identify the work location and equipment.
All possible voltage sources disconnected and re-connection locked out and tagged out?
All dangerous external voltages from the control circuits disconnected?
Waited 5 minutes after disconnecting power from the drive to let the intermediate circuit capacitors discharge?
Protected any other energized parts in the work location against contact?
Measured that the installation is de-energized using a quality voltage tester?
Voltage between the drive input power terminals (L1, L2, L3) and the grounding (PE) busbar is zero?
Voltage between the drive output terminals (T1/U, T2/V, T3/W) and the grounding (PE) busbar is zero?
3 Yearly R1- R2 Auxiliary Cooling Fan Replacement
Warning: This procedure requires a qualified electrical professional. Do not attempt if you are not qualified.
Electrical safety precautions
Clearly identified the work location and equipment
Disconnected all possible voltage sources and ensured re-connection is not possible
Protected any other energized parts in the work location against contact
Measured that the installation is de-energized using a quality voltage tester
Installed temporary grounding as required by the local regulations
Obtained a permit to work from the person in control of the electrical installation work
Replacing the auxiliary cooling fan, IP55 (UL Type 12) frames R1...R2
1 Yearly Heatsink Cleaning
Electrical safety in installation, start-up and maintenance
Electrical safety precautions
WARNING! Obey these instructions. If you ignore them, injury or death, or damage to the equipment can occur.
If you are not a qualified electrical professional, do not do installation or maintenance work.
Do these steps before you begin any installation or maintenance work.
Clearly identify the work location and equipment.
Disconnect all possible voltage sources. Make sure that re-connection is not possible. Lock out and tag out.
Protect any other energized parts in the work location against contact.
Take special precautions when close to bare conductors.
6 Yearly R3 Auxiliary Cooling Fan Replacement
Warning: This procedure requires a qualified electrical professional. Do not attempt if you are not qualified.
Before you begin any installation or maintenance work, follow these steps:
Clearly identify the work location and equipment.
Disconnect all possible voltage sources. Make sure that re-connection is not possible. Lock out and tag out.
Protect any other energized parts in the work location against contact.
Take special precautions when close to bare conductors.
Measure that the installation is de-energized. Use a quality voltage tester.
Install temporary grounding as required by the local regulations.
Ask for a permit to work from the person in control of the electrical installation work.
20 Yearly Functional Safety Components Replacement
Warning: This procedure requires trained personnel with PPE!
Are all components within their mission time?
If any component is beyond its mission time, proceed with the following steps
Choose the type of service done
Enter the age of the oldest component in the circuit
Did the circuit pass the post-replacement test?
Issues found during the test
Sign off on the safety components replacement
Access the parts list for your equipment in MaintainX.
Phoenix Contact Subcon-Plus-Profib/PG/SC2
2708245
Profibus Bus Connector
6GK1 500 0EA02
Fuse, ABB Type
OFAF2H425
Fuse, Bussmann Type, DIN 43620 Blade Style
170M6812D
Fuse, Bussmann Type, DIN 43653 Bolted Tags
170M5010
Phoenix Contact Subcon-Plus-Profib/PG/SC2
2708245
Profibus Bus Connector
6GK1 500 0EA02
Fuse, ABB Type
OFAF2H425
Fuse, Bussmann Type, DIN 43620 Blade Style
170M6812D
Fuse, Bussmann Type, DIN 43653 Bolted Tags
170M5010
Phoenix Contact Subcon-Plus-Profib/PG/SC2
2708245
Profibus Bus Connector
6GK1 500 0EA02
Fuse, ABB Type
OFAF2H425
Fuse, Bussmann Type, DIN 43620 Blade Style
170M6812D
Fuse, Bussmann Type, DIN 43653 Bolted Tags
170M5010
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX