Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

York Single Package Air Conditioner ZF150N54B7A1BAA1A1
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
Joints Leaks Check
Safety Warning
Natural gas may contain some propane. Propane is an excellent solvent and will quickly dissolve white lead and most standard commercial compounds. A special pipe dope must be used when assembling wrought iron or steel pipe. Shellac based compounds such as Gaskolac or Stalastic, and compounds such as Rectorseal #5, Clydes’s or John Crane may be used.
Open the main shut-off valve admitting normal gas pressure to the mains.
Check all joints for leaks with soap solution or other material suitable for the purpose. NEVER USE A FLAME.
Fire or Explosion Hazard Warning
Never test for gas leaks with an open flame. Use a commercially available soap solution made specifically for the detection of leaks to check all connections. A fire or explosion may result causing property damage, personal injury or loss of life.
Manifold Gas Pressure Maintenance
Preparation
Turn off all power to the unit
Connect a manometer to the outlet pressure port on the gas valve
Remove plastic cap covering HI and LO pressure adjustment screws
Second Stage Pressure Adjustment
Turn on power to the unit
Set thermostat to call for second stage heat and start furnace
Adjust second stage adjustment screw to set manifold pressure
Is the second stage manifold pressure within 3.5 IWG ± 0.3?
Gas Piping Cleaning
WARNING!
Pipe Cleaning
Clean all piping of dirt and scale by hammering on the outside of the pipe.
Blow out loose particles from the piping.
Pre-Start-up Check
Have all gas lines external to the unit been purged of air?
Initial Equipment Inspection
Inspect unit for possible damage during transit
Note extent of damage on carrier’s freight bill if damage is evident
Request inspection by the carrier’s agent in writing
Ensure compliance with installation instructions and applicable codes
Disconnect furnace and shut-off valve from gas supply piping system for pressure testing above 1/2 PSIG
Replace gas valve if subjected to pressure greater than 1/2 PSIG
Isolate furnace from gas supply piping system by closing manual shut-off valve for pressure testing at or below 1/2 PSIG
Burner and Orifice Inspection
Preparation
Close main manual shut-off valve
Shut off all power to the unit
Disassemble Gas Line and Manifold
Open the union fitting upstream of the unit gas valve and downstream from the main manual shut-off valve
Remove screws holding each end of the manifold to the manifold supports
Disconnect wiring to the gas valves and spark igniters
Remove the manifold & gas valve assembly
Orifice Inspection/Replacement
Access the parts list for your equipment in MaintainX.
UP Accessory Kit
1GP0405
LP Gas Conversion Kit
1NP0442
Optional CO2 Space Sensor Kit
2AQ04700524
Optional CO2 Sensor Kit
2AQ04700624
Mobile Access Portal (MAP) Gateway (Portable) Source 1
S1-JC-MAP1810-OP
UP Accessory Kit
1GP0405
LP Gas Conversion Kit
1NP0442
Optional CO2 Space Sensor Kit
2AQ04700524
Optional CO2 Sensor Kit
2AQ04700624
Mobile Access Portal (MAP) Gateway (Portable) Source 1
S1-JC-MAP1810-OP
UP Accessory Kit
1GP0405
LP Gas Conversion Kit
1NP0442
Optional CO2 Space Sensor Kit
2AQ04700524
Optional CO2 Sensor Kit
2AQ04700624
Mobile Access Portal (MAP) Gateway (Portable) Source 1
S1-JC-MAP1810-OP
MaintainX Assist is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX