York Single Package Cooling Unit ZE060E12B2A1ABA1A2
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
Manifold Gas Pressure Maintenance
Remove the adjustment screw cap(s) on the regulator
Adjust the gas pressure
To decrease the gas pressure, turn the adjusting screw counterclockwise
To increase the gas pressure, turn the adjusting screw clockwise
Replace adjustment screw caps
Enter the current manifold pressure
Is the manifold pressure set to the factory standard of 3.50 IWG?
If the manifold pressure is not set to 3.50 IWG, describe the adjustments made
Initial Equipment Inspection
Inspect unit for possible damage during transit
Note extent of damage on carrier’s freight bill if damage is evident
Request inspection by the carrier’s agent in writing
Ensure compliance with installation instructions and applicable codes
Disconnect furnace and shut-off valve from gas supply piping system for pressure testing above 1/2 PSIG
Replace gas valve if subjected to pressure greater than 1/2 PSIG
Isolate furnace from gas supply piping system by closing manual shut-off valve for pressure testing at or below 1/2 PSIG
Burner Replacement
Ensure all safety precautions are in place
Remove screws holding the manifold to the burner supports
Open the union fitting in the gas supply line
Remove the gas piping closure panel
Disconnect wiring to the gas valves and spark ignitors
Remove the manifold-burner gas valve assembly
Check burners for accessibility and service
Reverse the procedure to replace the assemblies
Ensure burners are level and seated at the rear of the heat exchanger
Gas Piping Cleaning
WARNING!
Ensure the use of appropriate pipe dope
Pipe Cleaning
Clean piping of dirt and scale by hammering on the outside of the pipe
Blow out loose particles from the pipe
Purge all gas lines external to the unit of air before initial start-up
Joints Leaks Check
Safety Warning
Natural gas may contain some propane. Propane is an excellent solvent and will quickly dissolve white lead and most standard commercial compounds. A special pipe dope must be used when assembling wrought iron or steel pipe. Shellac based compounds such as Gaskolac or Stalastic, and compounds such as Rectorseal #5, Clydes’s or John Crane may be used.
Open the main shut-off valve admitting normal gas pressure to the mains.
Check all joints for leaks with soap solution or other material suitable for the purpose. NEVER USE A FLAME.
Never test for gas leaks with an open flame. Use a commercially available soap solution made specifically for the detection of leaks to check all connections.
Confirm no leaks were detected
If leaks are detected, describe the location and severity
Fire or Explosion Hazard Warning
Failure to follow the safety warning exactly could result in serious injury, death or property damage. A fire or explosion may result causing property damage, personal injury or loss of life.
Access the parts list for your equipment in MaintainX.
LP Gas Accessory Kit
1NP0440
LP Gas Accessory Kit(2 Stage)
1NP0485
Ducted Systems Accessory Kit
1GP0401
Optional CO2 Space Sensor Kit
2AQ04700524
Optional CO2 Sensor Kit
2AQ04700624
LP Gas Accessory Kit
1NP0440
LP Gas Accessory Kit(2 Stage)
1NP0485
Ducted Systems Accessory Kit
1GP0401
Optional CO2 Space Sensor Kit
2AQ04700524
Optional CO2 Sensor Kit
2AQ04700624
LP Gas Accessory Kit
1NP0440
LP Gas Accessory Kit(2 Stage)
1NP0485
Ducted Systems Accessory Kit
1GP0401
Optional CO2 Space Sensor Kit
2AQ04700524
Optional CO2 Sensor Kit
2AQ04700624
MaintainX Assist is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX