MaintainX, an Autodesk company
EnterprisePricing
Lennox

Lennox HVAC Unit LGT156H5M

Need answers fast?
Explore the manual using AI.

Lennox HVAC Unit LGT156H5M
Lennox HVAC Unit LGT156H5M

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Lennox HVAC Unit LGT156H5M

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Lennox HVAC Unit LGT156H5M

Lennox HVAC Unit LGT156H5M

Create an account to install this asset package.

Maintenance Plans for Lennox HVAC Unit Model LGT156H5M

Integrate maintenance plans directly into your work orders in MaintainX.

Evaporator Coil Maintenance

Check mark

Pre-Inspection Requirements

Check mark

Check with gas company or authorities for local code requirements

Check mark

Refer to the LGT Installation, Operation and Maintenance instruction

Check mark

Coil Inspection and Cleaning

Check mark

Inspect coil at the beginning of each season

Check mark

Clean coil using mild detergent or commercial coil cleanser

Check mark

Condensate Drain Inspection

Check mark

Check condensate drain pan and line

Check mark

Flush coil and condensate drain with water

Run this procedureArrow right

1 Yearly Air Blower Wheel Inspection

Check mark

Check with gas company or authorities for local code requirements

Check mark

Refer to the LGT Installation, Operation and Maintenance instruction

Check mark

Turn off power before removing access panel or cleaning blower wheel

Check mark

Inspect supply air blower wheel for accumulated dirt or dust

Check mark

Clean the blower wheel if dirt or dust is present

Run this procedureArrow right

Gas Piping Check

Check mark

Verify local code requirements with gas company or authorities

Check mark

Check the LGT Installation, Operation and Maintenance instruction

Check mark

Measure the pressure drop between the gas meter and the unit

Check mark

Is the pressure drop less than or equal to 0.5”W.C.?

Check mark

Ensure the supply gas pipe is not smaller than the unit gas connection

Run this procedureArrow right

HVAC Unit Check

Check mark

Preliminary and Seasonal Checks

Check mark

Ensure the unit is installed according to installation instructions and applicable codes.

Check mark

Inspect all electrical wiring for loose connections and tighten as required.

Check mark

Check refrigerant lines for good condition and ensure they do not rub against the cabinet or other lines.

Check mark

Check voltage to ensure it is within the range listed on the nameplate.

Check mark

Is the voltage within the range listed on the nameplate?

Check mark

Recheck voltage and amp draw with unit running.

Check mark

Is the voltage within range while the unit is running?

Check mark

Inspect and adjust blower belt.

Run this procedureArrow right

Gas Piping Testing

Check mark

Verify local code requirements

Check mark

Review LGT Installation, Operation and Maintenance instruction

Check mark

Emergency shutdown procedure

Check mark

Pressure testing preparation

Check mark

Check piping connection for gas leaks

Check mark

Use of Gas Leak Detector

Check mark

Avoid ignition sources

Run this procedureArrow right

Parts for Lennox HVAC Unit LGT156H5M

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

Gas Leak Detector

31B2001

Filter Handicoater, R.P. Products Coating No. 418

P-8-5069

Bipolar Ionizer

622688-03

Gas Leak Detector

31B2001

Filter Handicoater, R.P. Products Coating No. 418

P-8-5069

Bipolar Ionizer

622688-03

Gas Leak Detector

31B2001

Filter Handicoater, R.P. Products Coating No. 418

P-8-5069

Bipolar Ionizer

622688-03

Unlock
efficiency with MaintainX Assist

MaintainX Assist is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Lennox