Lennox HVAC Unit LGT156H5M
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
Evaporator Coil Maintenance
Pre-Inspection Requirements
Check with gas company or authorities for local code requirements
Refer to the LGT Installation, Operation and Maintenance instruction
Coil Inspection and Cleaning
Inspect coil at the beginning of each season
Clean coil using mild detergent or commercial coil cleanser
Condensate Drain Inspection
Check condensate drain pan and line
Flush coil and condensate drain with water
1 Yearly Air Blower Wheel Inspection
Check with gas company or authorities for local code requirements
Refer to the LGT Installation, Operation and Maintenance instruction
Turn off power before removing access panel or cleaning blower wheel
Inspect supply air blower wheel for accumulated dirt or dust
Clean the blower wheel if dirt or dust is present
Gas Piping Check
Verify local code requirements with gas company or authorities
Check the LGT Installation, Operation and Maintenance instruction
Measure the pressure drop between the gas meter and the unit
Is the pressure drop less than or equal to 0.5”W.C.?
Ensure the supply gas pipe is not smaller than the unit gas connection
HVAC Unit Check
Preliminary and Seasonal Checks
Ensure the unit is installed according to installation instructions and applicable codes.
Inspect all electrical wiring for loose connections and tighten as required.
Check refrigerant lines for good condition and ensure they do not rub against the cabinet or other lines.
Check voltage to ensure it is within the range listed on the nameplate.
Is the voltage within the range listed on the nameplate?
Recheck voltage and amp draw with unit running.
Is the voltage within range while the unit is running?
Inspect and adjust blower belt.
Gas Piping Testing
Verify local code requirements
Review LGT Installation, Operation and Maintenance instruction
Emergency shutdown procedure
Pressure testing preparation
Check piping connection for gas leaks
Use of Gas Leak Detector
Avoid ignition sources
Access the parts list for your equipment in MaintainX.
Gas Leak Detector
31B2001
Filter Handicoater, R.P. Products Coating No. 418
P-8-5069
Bipolar Ionizer
622688-03
Gas Leak Detector
31B2001
Filter Handicoater, R.P. Products Coating No. 418
P-8-5069
Bipolar Ionizer
622688-03
Gas Leak Detector
31B2001
Filter Handicoater, R.P. Products Coating No. 418
P-8-5069
Bipolar Ionizer
622688-03
MaintainX Assist is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX