PDF MANUAL

Manual for York Medium Voltage Variable Speed Drive MVVSD30002K-84

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

York Medium Voltage Variable Speed Drive MVVSD30002K-84

York Medium Voltage Variable Speed Drive MVVSD30002K-84

Create an account to install this asset package.

Maintenance Plans for York Medium Voltage Variable Speed Drive Model MVVSD30002K-84

Integrate maintenance plans directly into your work orders in MaintainX.

Electrical Insulation Check

Check mark

Preparation

Check mark

Ensure all switches and circuit breakers are opened

Check mark

Disconnect devices not intended for dielectric test, such as input surge suppressors

Check mark

Dielectric Test

Check mark

Perform dielectric test at 2.25 times the nominal system voltage plus 2,000 V phase-to-ground and phase-to-phase

Check mark

Is the light or buzzer calibrated to indicate failure with an output current between 1.5 mA and 2.0 mA for every 1,000 V applied?

Check mark

Check for hazardous voltages during dielectric testing

Check mark

Post-Test Procedures

Check mark

Set all devices to their normal off position before energizing incoming power

Run this procedureArrow right

Drive Pre-Energization Check

Check mark

Verify MVVSD Ratings

Check mark

Verify MVVSD ratings match system data

Check mark

Check the connections

Check mark

Remove all blocks or temporary braces used for shipment

Check mark

Clean Enclosure

Check mark

Clean out all metal chips, scrap wire, and other debris

Check mark

Is there an appreciable accumulation of dust or dirt?

Check mark

Clean the enclosure using a brush, vacuum cleaner, or a clean lint-free brush

Check mark

Check the integrity of all bus bar supports for secureness and damage

Run this procedureArrow right

Drive Inspection

Check mark

Initial Inspection

Check mark

Remove any transit packing

Check mark

Inspect the unit to ensure all components have been delivered

Check mark

Check for any damage occurred during transit

Check mark

Damage Reporting

Check mark

Note any damage on the carrier's freight bill

Check mark

Enter a claim for any evident damage

Check mark

Report major damage to the local Johnson Controls representative

Check mark

Safety Precautions

Run this procedureArrow right

Device and Mechanism Check

Check mark

Device Inspection and Repair

Check mark

Check all devices for damage

Check mark

Describe necessary repairs or replacements made

Check mark

Ensure all safety signs are visible and not obscured

Check mark

Operating Mechanisms Check

Check mark

Manually exercise all switches, relays, and other operating mechanisms

Check mark

Check operating mechanisms for proper function

Check mark

Check fan overload relays for correct selection and adjustment

Check mark

Power Circuit Fuses Verification

Run this procedureArrow right

Drive Pre-Installation Check

Check mark

Verify drive specifications

Check mark

Follow all installation safety precautions

Check mark

Is the correct power source available?

Check mark

Does the installation site meet all environmental specifications for NEMA 1?

Check mark

Is the chiller in the correct working condition and ready to be started?

Check mark

Are power factor correction capacitors (PFCCs) located on the power source side of the drive?

Check mark

Ensure drive positioning allows ample clearance for cabinet doors and accessibility to controls

Check mark

Describe any issues found during the check

Run this procedureArrow right

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from York

Explore Other Assets