MaintainX Asset Hub logo
EnterprisePricing
York

York Heat Pump YHE36

Need answers fast?
Explore the manual using AI.

York Heat Pump YHE36
York Heat Pump YHE36

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for York Heat Pump YHE36

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

York Heat Pump YHE36

York Heat Pump YHE36

Create an account to install this asset package.

Maintenance Plans for York Heat Pump Model YHE36

Integrate maintenance plans directly into your work orders in MaintainX.

Heat Pump Charging

Check mark

CHARGING THE UNIT

Check mark

CAUTION

Check mark

Always charge in liquid form

Check mark

Take care not to slug the compressor

Check mark

The factory charge in the outdoor unit includes enough charge for the unit, 15 ft (4.6 m) of refrigerant piping, and the smallest indoor coil/air handler match-up

Check mark

Some indoor coil/air handler matches may require additional charge

Check mark

CAUTION

Check mark

Compressor damage will occur if system is improperly charged

Check mark

On new system installations, charge system per tabular data sheet for the matched coil and follow guidelines in this instruction

Run this procedureArrow right

Heat Pump Maintenance

Check mark

MAINTENANCE

Check mark

Dirt should not be allowed to accumulate on the outdoor coils or other parts in the air circuit. Clean as often as necessary to keep the unit clean. Use a brush, vacuum cleaner attachment, or other suitable means.

Check mark

The outdoor fan motor bearings are permanently lubricated and do not require periodic oiling.

Check mark

If the coil needs to be cleaned, it should be washed with Calgon Coilclean (mix one part Coilclean to seven parts water). Allow solution to remain on coil for 30 minutes before rinsing with clean water. Solution should not be permitted to come in contact with painted surfaces.

Check mark

Refer to the furnace or air handler instructions for filter and blower motor maintenance.

Check mark

The indoor coil and drain pan should be inspected and cleaned regularly to prevent odors and assure proper drainage.

Check mark

CAUTION: It is unlawful to knowingly vent, release or discharge refrigerant into the open air during repair, service, maintenance or the final disposal of this unit.

Check mark

Sign off on the heat pump maintenance

Run this procedureArrow right

Heat Pump Pre-start Check

Check mark

SYSTEM START-UP

Check mark

ENERGIZE CRANKCASE HEATER

Check mark

Set the indoor cooling thermostat to the OFF position

Check mark

Close the line power disconnect to the unit

Check mark

IMPORTANT: An attempt to start the compressor without at least 8 hours of crankcase heat will damage the compressor

Check mark

With power to unit and thermostat in cooling position

Check mark

In the cooling cycle, discharge gas is pumped to the outdoor coil which is the condenser. The indoor coil is the evaporator.

Check mark

If the fan switch is in ON position, a circuit is made through the blower relay to provide continuous blower operation

Check mark

With the fan switch in AUTO position, a circuit is made from the thermostat cooling contact through the blower relay to provide blower operation

Run this procedureArrow right

Parts for York Heat Pump YHE36

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

R-410A Filter-Drier

S1-52636219000

R-410A Filter-Drier

S1-52636219000

R-410A Filter-Drier

S1-52636219000

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from York

Explore Other Assets