Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

York Screw Chiller YCIV0327VA46
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
1 Yearly Chiller Maintenance
This procedure must be performed at the specified time by an industry certified technician who has been trained and qualified to work on this type of equipment.
A record of this procedure being successfully carried out should be maintained on file by the equipment owner should proof of adequate maintenance be required at a later date for warranty purposes.
Sample compressor oil, check for acid, and replace if necessary
Disconnect power source and lock out and check tightness of power wiring connections
Check glycol concentration on low temperature or other applications where freezing may be a problem
Technician's Signature
6 Monthly Chiller Check
This procedure must be performed at the specified time by an industry certified technician who has been trained and qualified to work on this type of equipment
A record of this procedure being successfully carried out should be maintained on file by the equipment owner should proof of adequate maintenance be required at a later date for warranty purposes
Check superheat on the evaporator and the economizer feed to the compressor
Check condenser subcooling
Leak check the chiller
Technician's signature
Date of procedure
Chiller Soap Visual Gas Leak Test
Warning: This procedure requires trained personnel with PPE!
Enter the system pressure
All system valves including manual valves and EEVs are 100% open
All valves to the atmosphere are closed with flare caps in place
Enter the unit's initial evacuation level
Enter the system pressure after charging with dry nitrogen
Soap and water solution prepared
Soap solution test performed on each unit fitting joint and weld seams
Ultrasonic leak detector used
Chiller Refriegerant Charging
Warning: Ensure the vapor portion of the refrigerant container or cylinder has not been contaminated with other gases that are not R-134a, including air.
Is the appropriate saturation property for the correct refrigerant used?
Refer to Table 55 on page 314 for R-134a to determine if the saturation pressure and ambient temperature of the refrigerant in the container coincide.
Is only refrigerant vapor from the top of the drum or cylinder admitted to the system until system pressure is raised above the corresponding saturation pressure at the freezing point of the chilled liquids?
Enter the freeze point temperature and vapor charge to a pressure that is 5°F (2.78°C) higher than that freeze point.
Enter the starting weight for the refrigerant cylinder.
Is a refrigerant pump used to draw vapor from the chiller and discharge it to the vapor connection of the refrigerant cylinder?
Is air prevented from entering the system?
Is a suitable charging connection created using new copper tubing or correctly selected flexible charging hoses?
Chiller Gas Pressure Hold Test
System pressure test
Refrigerant charge removed and all known leaks repaired?
System charged with a small amount of refrigerant mixed with dry nitrogen?
Used an electronic leak detector to detect any leaks that are too small to be found by the soap test?
Rated pressure of the unit refrigerant pressure relief valves not exceeded?
Conducting the gas pressure hold test
High-quality, high-resolution analog pressure gauge installed on one of the service valves?
All the system valves including manual valves and EEVs are 100% open?
All valves to the atmosphere are closed with flare caps in place, if applicable?
Access the parts list for your equipment in MaintainX.
York Coolant, Approved Coolant
013-03344-000
Isolator One Inch Deflection Rated Capacity Up To 434 Lb Up To 197 Kg Color Black
029-25334-002
Isolator One Inch Deflection Rated Capacity 435–765 Lb 198–347 Kg Color Dk Green
029-25334-003
Isolator One Inch Deflection Rated Capacity 766–1020 Lb 348–463 Kg Color Gray
029-25334-004
Isolator One Inch Deflection Rated Capacity 1021–1156 Lb 464–524 Kg Color White
029-25334-005
York Coolant, Approved Coolant
013-03344-000
Isolator One Inch Deflection Rated Capacity Up To 434 Lb Up To 197 Kg Color Black
029-25334-002
Isolator One Inch Deflection Rated Capacity 435–765 Lb 198–347 Kg Color Dk Green
029-25334-003
Isolator One Inch Deflection Rated Capacity 766–1020 Lb 348–463 Kg Color Gray
029-25334-004
Isolator One Inch Deflection Rated Capacity 1021–1156 Lb 464–524 Kg Color White
029-25334-005
York Coolant, Approved Coolant
013-03344-000
Isolator One Inch Deflection Rated Capacity Up To 434 Lb Up To 197 Kg Color Black
029-25334-002
Isolator One Inch Deflection Rated Capacity 435–765 Lb 198–347 Kg Color Dk Green
029-25334-003
Isolator One Inch Deflection Rated Capacity 766–1020 Lb 348–463 Kg Color Gray
029-25334-004
Isolator One Inch Deflection Rated Capacity 1021–1156 Lb 464–524 Kg Color White
029-25334-005
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.