York Screw Chiller YCIV0227VA46
York Screw Chiller YCIV0227VA46

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for York Screw Chiller YCIV0227VA46

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

York Screw Chiller YCIV0227VA46

York Screw Chiller YCIV0227VA46

Create an account to install this asset package.

Maintenance Plans for York Screw Chiller Model YCIV0227VA46

Integrate maintenance plans directly into your work orders in MaintainX.

Chiller System Dehydration

Check mark

Connect a high-capacity vacuum pump with indicator to the charging valves as shown in Figure 147 on page 306 and Figure 148 on page 306

Check mark

Start the pump

Check mark

Ensure all the system valves including manual valves and EEVs are 100% open

Check mark

Ensure that all valves to the atmosphere are closed with flare caps in place, if applicable

Check mark

Operate the vacuum pump until a pressure of 5,000 μm is reached

Check mark

To start the 8-hour vacuum hold test, close the system charging valve connection to the vacuum pump

Check mark

Note the time and pressure

Check mark

Hold the vacuum obtained in Step 4 in the system for 8 hours

Check mark

Check for pressure change with the chiller at the same temperature

Run this procedureArrow right

1 Daily Chiller Maintenance

Check mark

Daily maintenance

Check mark

The following maintenance checks should be carried out on a daily basis by the operator/customer

Check mark

The units are not generally user serviceable

Check mark

No attempt should be made to rectify faults or problems found during daily checks unless competent and equipped to do so

Check mark

If in any doubt, contact your local Johnson Controls Service Agent

Check mark

Unit status: Press the STATUS key on the keypad and ensure no fault messages are displayed

Check mark

Operating conditions: Read the operating pressures and temperatures at the control panel using the display keys

Check mark

Check that these are within the operating limitations given in the manual

Check mark

Compressor oil level: Check the compressor oil level after the compressor has been operating on FULL LOAD for approximately half an hour

Run this procedureArrow right

1 Weekly Chiller Check

Check mark

Check oil level in the oil separator sight glass

Check mark

Check liquid line sight glass / moisture indicator

Check mark

Record system operating temperatures

Check mark

Record system operating pressures

Check mark

Check condenser coils for dirt/debris

Check mark

Clean condenser coils if necessary

Check mark

Sign off on the weekly chiller check

Run this procedureArrow right

Chiller Refriegerant Charging

Check mark

Warning: Only trained personnel should perform this procedure.

Check mark

Is the vapor portion of the refrigerant container or cylinder free from contamination?

Check mark

Select the appropriate saturation property for the refrigerant

Check mark

Refer to Table 55 on page 314 for R-134a to determine if the saturation pressure and ambient temperature of the refrigerant in the container coincide.

Check mark

Is the system pressure raised above the corresponding saturation pressure at the freezing point of the chilled liquids?

Check mark

Enter the freeze point temperature

Check mark

Enter the vapor charge pressure

Check mark

Enter the starting weight for the refrigerant cylinder

Check mark

Is the chiller vapor charged to the appropriate saturation pressure?

Run this procedureArrow right

1 Yearly Chiller Maintenance

Check mark

This procedure must be performed at the specified time by an industry certified technician who has been trained and qualified to work on this type of equipment.

Check mark

A record of this procedure being successfully carried out should be maintained on file by the equipment owner should proof of adequate maintenance be required at a later date for warranty purposes.

Check mark

Sample compressor oil, check for acid, and replace if necessary.

Check mark

Disconnect power source and lock out and check tightness of power wiring connections.

Check mark

Check glycol concentration on low temperature or other applications where freezing may be a problem.

Check mark

Technician's Signature

Run this procedureArrow right

Parts for York Screw Chiller YCIV0227VA46

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

York Coolant, Approved Coolant

013-03344-000

Isolator One Inch Deflection Rated Capacity Up To 434 Lb Up To 197 Kg Color Black

029-25334-002

Isolator One Inch Deflection Rated Capacity 435–765 Lb 198–347 Kg Color Dk Green

029-25334-003

Isolator One Inch Deflection Rated Capacity 766–1020 Lb 348–463 Kg Color Gray

029-25334-004

Isolator One Inch Deflection Rated Capacity 1021–1156 Lb 464–524 Kg Color White

029-25334-005

York Coolant, Approved Coolant

013-03344-000

Isolator One Inch Deflection Rated Capacity Up To 434 Lb Up To 197 Kg Color Black

029-25334-002

Isolator One Inch Deflection Rated Capacity 435–765 Lb 198–347 Kg Color Dk Green

029-25334-003

Isolator One Inch Deflection Rated Capacity 766–1020 Lb 348–463 Kg Color Gray

029-25334-004

Isolator One Inch Deflection Rated Capacity 1021–1156 Lb 464–524 Kg Color White

029-25334-005

York Coolant, Approved Coolant

013-03344-000

Isolator One Inch Deflection Rated Capacity Up To 434 Lb Up To 197 Kg Color Black

029-25334-002

Isolator One Inch Deflection Rated Capacity 435–765 Lb 198–347 Kg Color Dk Green

029-25334-003

Isolator One Inch Deflection Rated Capacity 766–1020 Lb 348–463 Kg Color Gray

029-25334-004

Isolator One Inch Deflection Rated Capacity 1021–1156 Lb 464–524 Kg Color White

029-25334-005

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from York

Explore Other Assets