MaintainX, an Autodesk company
EnterprisePricing
Vulcan

Vulcan Heavy Duty Gas Griddle 972RX

Need answers fast?
Explore the manual using AI.

Vulcan Heavy Duty Gas Griddle 972RX
Vulcan Heavy Duty Gas Griddle 972RX

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Vulcan Heavy Duty Gas Griddle 972RX

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Vulcan Heavy Duty Gas Griddle 972RX

Vulcan Heavy Duty Gas Griddle 972RX

Create an account to install this asset package.

Maintenance Plans for Vulcan Heavy Duty Gas Griddle Model 972RX

Integrate maintenance plans directly into your work orders in MaintainX.

Griddle Level Calibration

Check mark

Leveling the Griddle

Check mark

Place a level on the griddle

Check mark

Adjust legs by turning the bullet feet at the bottom of each leg. Describe the adjustments made.

Check mark

Verification

Check mark

Is the griddle level from side-to-side?

Check mark

Is the griddle level from front-to-back?

Check mark

Final Check

Check mark

Is the temperature distribution even across the griddle?

Check mark

Check for any visible damage to electrical components.

Run this procedureArrow right

Momentary Power Switch Replacement

Check mark

WARNING! Disconnect the electrical power to the machine and follow lockout / tagout procedures

Check mark

Remove FRONT PANEL

Check mark

Label and disconnect wires from power switch

Check mark

Squeeze switch retainers and slide switch out through front of panel

Check mark

Install new switch in reverse order

Check mark

Verify the switch is securely installed

Check mark

Reconnect wires to the new power switch

Check mark

Reattach FRONT PANEL

Check mark

Test the new power switch functionality

Run this procedureArrow right

Thermocouple Testing

Check mark

Unscrew thermocouple fitting from safety valve

Check mark

Install thermocouple test adapter finger tight plus a quarter turn

Check mark

Install thermocouple into test adapter finger tight plus a quarter turn

Check mark

Set VOM to DC millivolt scale and connect (+) meter lead to pin on thermocouple adapter and (-) meter lead to thermocouple

Check mark

Light pilot flame

Check mark

Verify that thermocouple is sufficiently immersed in flame. Adjust pilot valve to allow more gas flow if necessary

Check mark

Allow pilot to burn for 3-4 minutes to stabilize voltage output from thermocouple

Check mark

Verify thermocouple output voltage

Check mark

Enter the measured thermocouple output voltage

Run this procedureArrow right

Gas Pressure Measurement Service

Check mark

WARNING! All gas joints disturbed during servicing must be checked for leaks. Check with a soap and water solution (bubbles). Do not use an open flame

Check mark

Turn the gas supply off at a manual shutoff valve

Check mark

Remove the control panel

Check mark

Remove the pressure tap plug and attach manometer

Check mark

Turn gas back on

Check mark

Light pilot(s)

Check mark

Turn all thermostats on to the maximum setting so that all burners are on

Check mark

Turn all the equipment on the same supply line on

Check mark

Check gas pressure

Run this procedureArrow right

Gas Pressure Regulator Adjustment

Check mark

Regulator Installation

Check mark

Ensure the regulator is installed close to the griddle on the gas supply line.

Check mark

Verify the arrow on the underside of the regulator is oriented in the direction of gas flow to the griddle.

Check mark

Check that the regulator is positioned with the vent plug and adjustment screw upright.

Check mark

Vent Plug Inspection

Check mark

Inspect the vent plug for clogs from grease and debris.

Check mark

Gas Pressure Setting

Check mark

Measure the gas pressure after the regulator is installed.

Check mark

Set the gas pressure for the type of gas used

Run this procedureArrow right

Parts for Vulcan Heavy Duty Gas Griddle 972RX

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

Aluminum Foil Tape

7631421

Adapter

H23-226

Aluminum Foil Tape

7631421

Adapter

H23-226

Aluminum Foil Tape

7631421

Adapter

H23-226

Unlock
efficiency with MaintainX Assist

MaintainX Assist is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Vulcan

Explore Other Assets